Unipower繼電器 HPL110 UL94V-1

批發(fā)數(shù)量
梯度價格
型號
UL94V-1
品牌
Unipower
應(yīng)用范圍
功率
產(chǎn)品系列
3RP10
觸點負載
中功率
觸點切換電流
10
觸點切換電壓
12
觸點形式
七開一閉
額定電流
5
額定電壓
AC200-240
防護特征
敞開式
吸合電流
36
電流性質(zhì)
交流
釋放電流
24

www.novosor.com廣州市朝德機電設(shè)備有限公司專業(yè)經(jīng)銷歐美各種進口電器配件,工業(yè)備品備件。有業(yè)務(wù)請直接聯(lián)系:T:020-83191853  F:020-83190556  QQ:2418487878  EMAIL:novosor@163.com  聯(lián)系人:吳學(xué)斌專業(yè)代理經(jīng)銷:
 
 
 
Unipower繼電器HPL110
is among the leading products when it comes to digital
and analogue load monitors and measurement transducers
Technical data
Mechanical
Housing: Makrolon UL94V-1 (housing)
Makrolon UL94V-2 (konnector)
Mounting: 35 mm DIN rail- or wall mounting
IP class: Housing IP40
Connector IP20
Temp range: -15 to +50
o
C
Weight: 400 g
Dimensions:D 75 x B 56 x H 110 mm
UL certif.: UL508. File E190959
Electrical
Supply/measurement: See technical info on the unit
Available: 3x120 to 3x575V~
Current range: Internal max 8 A~
Eksternal N/1 or N/5 A~
Frequency range: 50/60 Hz
Consumption: 3 VA
Relay output: 250V~/5A~
Analogue output: 4-20 mA max 400 ohm
CE mark to: EN50081-1, EN50082-2,
EN61010-1
Load monitor with Max./Min. limit
Unipower HPL110
Generally
Low cost kW-meter with built-in functions
for control and supervision of AC-motor
driven equipment. A very popular and
inexpensive unit. The more advanced
functions implemented in our HPL400
family are not present in this unit. The unit
is used by several manufacturers of pumps,
conveyors and special machinery. Some of
these have their own logo on the front plate.
This is also an option for future customers.
Features
* kW[%] measurement
* Digital programming
* Start timer 0,1-99.9 sek
* Reaction timer 20ms-99.9 sek
* Max. limit 5-100%
* Min. limit 5-100%
* 2-points regulation
* Built-inPeak detector
Applications
* Pump supervision (Max. and Min.).
* Supervision of conveyor belts.
* Simple overload supervision of
cranes.
* 2-points regulation via hysteresis on
the Max.- or the Min.-limit.
* Other machinery where an alarm is
required on a given motor torque
(Max. and Min.).
Hydria Elektronik ApS Tlf: 98293433 Home page:
Følfodvej 36 Fax: 98293286 E-mail: hydria@unipower.dk
Dk-9310 Vodskov
Unipower product program
Units for DIN-rail mounting (35mm) or panel mounting
(72 x 72).
Measurement transducers: 1- and 3-phased kW-
measurement. Symmetric and asymmetric. Before and
after frequency inverters. Analogue output (4-20mA)
as well as pulse output (kWh).
Load monitors: 3-phased symmetric kW-measure-
ment. Programmable kw-limits: Max., Min and dP/dt.
Support functions: Start timer, reaction timer, hyste-
resis, auto reset, manual reset, alarm blocking etc.
Analogue output (4-20mA).
Tool supervision: Kompact units for supervision of
up to 16 cut. Measurement of power and work for
break, wear and missing tool. Monitoring program for
installation and statistics, for DOS or Windows.
Typical wiring
The Figure above shows a typical AC-motor power
consumption curve immediately after power has been
applied to the motor. The bars at the bottom of the figure
indicate power applied to the unit and the position/state
of the relay (On/Off). The figure shows the functions
and the parameters of the HPL110 in two different
situations; hysteresis on the Max. limit and hysteresis on
the Min. limit. Note that the use of hysteresis on the Min.
limit requires the Max. limit to be Off.
3
M
~
L1
L2
L3
Motor
In>8Amp.
ExternalC.T.
Fuses
Aut.Reset
Ext.Reset
K
9
11
13
14
15
NC
C
NO
S1
S2 16
1
3
5
7
8
L1
L2
L3
k
l
HPL110
10
Gnd
Only ifmin. limit used
12
P[%]
100%
75%
50%
25%
Threshold 5%
PowerOn
RelayOn
Ts
Tr
Tr
t
Auto-Reset
Auto-Reset
Min.Hyst’sband
Max.Hyst’sband
Min. limit
Max. limit
P=f(t)
Note! The Max. limit must be Off
when using hysteresis on the Min. limit