詳細信息
********************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************
1.Features產(chǎn)品特性
使用中若發(fā)生過載異常時發(fā)揮保險絲功能
符合安規(guī)UL-94V-O要求
Coating meets UL-94V-0
符合無鉛/ROHS要求
Lead-free and ROHS compliant
Characteristics | Standard | Test Methods | |||||
1. Resistance Temperature Coefficient (PPM/℃) | ±300PPM/℃ | Natural resistance change per temperature degree centigrade. (PPM/℃) R1: Resistance value at reference temperature. (T1) R2: Resistance value at reference temperature. (T2) T1: Room Temperature T2: T1±100℃ | |||||
2. Dielectric Withstanding Voltage | No evidence of flashover, mechanical damage or arcing or, insulation break down. | Resistors shall be subjected to an approximately sinusoidal test potential (as below) 60Hz applied between both terminals connected together and a 90° V-Block extending beyond the end of the resistor. | |||||
Resistor Wattage | DC Volts | ||||||
1/2W(1WS) 1W,2W Above | 350 600 | ||||||
3. Solderability | 90% Covered min. | The terminal lead shall be dipped into molten solder s at 3.2 to 4.8mm from the body of resistor.The temp. and time as below: a. 260±5℃for 2±0.5 seconds b. 350±10℃for 2±0.5seconds | |||||
4. Resistance to Soldering | No evidence of mechanical damage △ R/R±5% | The terminal of the resistor is dipped into the molten solder of 350±10℃for 3±0.5 seconds. Then put the resistor in the room temperature. For min.3 hours. | |||||
5. Humidity Load Life | ±5% Max./1000Hours | Resistance change after 1000 hours ( 1.5 hours on 0.5 hours off)at rated continuous working voltage in a humidity chamber controlled at 40±2℃and 90~95% relative humidity . | |||||
6. Load Life | ±5% Max./1000Hours | Permanent resistance change after 1000 hours operating at rated continuous working voltage with a duly cycle of 1.5 hours on 0.5 hours off at 70 ± 2℃ambient . | |||||
7. Temperature Cycling | Δ R/R at±1% Max.No evidence of mechanical damage. | Resistance change after continuous five cycles for duty cycle as specified below. | |||||
Step | Temperature | Time | |||||
1 | -30℃ | 30 Minutes | |||||
2 | +25℃ | 10~15 Minutes | |||||
3 | +85℃ | 30 Minutes | |||||
4 | +25℃ | 10~15 Minutes | |||||
Characteristics | Standard | Test Methods | |||||
8. Short Time Overload | ΔR/R at±2% Max. with no evidence of arcing burning, or charring | Permanent resistance change after the application of a potential of 2.5 times rated continuous working voltage for 5 seconds at room temperature. | |||||
9. Terminal Strength | No evidence of mechanical damage or loosening terminals | Direct load resistance to 2.5kg direct load 30±5 seconds twist test, for axial leads unit only. Terminal lead shall be bent through at a right angle at a point of 6.35mm from the body edge of resistor and shall be rotated through at a right angle about the original axis of the bent terminal in alternating direction for a total 3 rotations. |