26
Altera Corporation
MAX 9000 Programmable Logic Device Family Data Sheet
Notes to tables:
(1)
See the
Operating Requirements for Altera Devices Data Sheet
in this data book.
(2)
Minimum DC input on I/O pins is –0.5 V and on the four dedicated input pins is –0.3 V. During transitions, the
inputs may undershoot to –2.0 V or overshoot to 7.0 V for periods shorter than 20 ns under no-load conditions.
(3)
V
CC
must rise monotonically.
(4)
Numbers in parentheses are for industrial-temperature-range devices.
(5)
Typical values are for T
A
= 25
°
C and V
CC
= 5.0 V.
(6)
These values are specified under the MAX 9000 recommended operating conditions, shown in
Table 12 on page 24
.
(7)
This parameter is measured with 50
%
of the outputs each sinking 12 mA. The I
OH
parameter refers to high-level
TTL or CMOS output current; the I
OL
parameter refers to the low-level TTL or CMOS output current.
(8)
JTAG pin input leakage is typically –60
μΑ
.
(9)
Capacitance is sample-tested only and is measured at 25
°
C.
(10) Measured with a 16-bit loadable, enabled, up/down counter programmed into each LAB. I
CC
is measured at 0
°
C.
Figure 13
shows typical output drive characteristics for MAX 9000
devices with 5.0-V and 3.3-V V
CCIO
.
Figure 13. Output Drive Characteristics of MAX 9000 Devices
Note (1)
Note:
(1)
Output drive characteristics include the JTAG
TDO
pin.
Table 17. MAX 9000A Device Typical I
CC
Supply Current Values
Symbol
Parameter
Conditions
EPM9320A EPM9560A Unit
I
CC1
I
CC
supply current (low-power
mode, standby, typical)
V
I
= ground, no load
(10)
99
174
mA
1
2
3
4
5
30
60
90
150
120
V
= 5.0 V
Room Temperature
I
OL
I
OH
1
2
3
4
5
30
60
90
150
120
V
CCIO
= 3.3 V
Room Temperature
I
OL
I
OH
3.3
Typical I
Output
Current (mA)
Output Voltage (V)
Output Voltage (V)
O
Typical I
Output
Current (mA)
O
5.0-V
3.3-V