EMC TECHNOLOGY
CAGE CODE # 24602
DWG #
1009725000
8851 SW OLD KANSAS AVE.
CHANGE NOTICE
EN 04-E033
REV LVL
-
STUART, FL 34997
SHEET
2
OF
3
TCA =
SLOPE
.
ATTENUATION @ 25°C
3.3.1.6.3 ACCEPTANCE LIMITS: NOMINAL TCA +/-0.001 dB/dB/°C.
3.2.2
GROUP B TESTING (7 SAMPLES APPROVED FROM GROUP A).
3.2.2.1
SUB-GROUP 1 (3 SAMPLES)
3.2.2.1.1 LOW TEMPERATURE OPERATION
3.2.2.1.1.1
USE FINAL ELECTRICAL MEASUREMENTS FROM GROUP A.
3.2.2.1.1.2
DISSIPATE LOW POWER FOR A DURATION OF 45 +5/-0 MINUTES.
ALLOW TO STABILIZE AT 25°C FOR 24 HOURS.
3.2.2.1.2 AFTER LOW TEMPERATURE ELECTRICAL MEASUREMENTS - MEASURE AND
RECORD VSWR @ 1 GHZ AND ATTENUATION AT DC (0 GHZ) AND 1.0 GHZ.
3.2.2.1.3 HIGH TEMPERATURE BAKE – +125°C +/- 5°C FOR 100 HRS THEN STABILIZE AT 25°C
FOR 4 HRS.
3.2.2.1.3.1
VISUAL EXAMINATION - INSPECT FOR EVIDENCE OF MECHANCIAL
DAMAGE.
3.2.2.1.4 AFTER HIGH TEMPERATURE BAKE ELECTRICAL TEST - MEASURE AND RECORD
VSWR @ 1 GHZ AND ATTENUATION AT DC (0 GHZ) AND 1.0 GHZ.
3.2.2.1.5 TERMINATION ADHESION - SOLDER A WIRE AND PULL WITH 15 GRAMS
PERPENDICULAR TO AND AWAY FROM THE SURFACE AREA.
3.2.2.1.5.1
VISUAL INSPECTION – THERE SHALL BE NO SEPARATION OF
MATERIAL.
3.2.2.1.6 BONDABILITY
3.2.2.1.6.1
WIREBOND TEST WITH .001 DIAMETER GOLD WIRE USING ULTRSONIC
THERMAL COMPRESSION AT A TEMPERATURE OF +150°C +/- 3°C.
3.2.2.1.7 PULL TEST -TEST TO FAILURE. STRENGTH AND MODE OF FAILURE SHALL BE
RECORDED. SEE PARAGRAPH 3.1.6.2 AND 3.1.6.3 OF TP-8965.
3.2.2.2
SUB-GROUP 2 (4 SAMPLES)
3.2.2.2.1 INITIAL RF MEASUREMENTS - USE FINAL ELECTRICAL MEASUREMENTS FROM
GROUP A.
3.2.2.2.2 LIFE TEST – OPERATE SAMPLES UNITS FOR 1000 HRS AT 70°C AT INPUT POWER
PER 1.1.6. ELECTRICAL MEASUREMENTS SHALL BE MADE AT 250 +48/-0 HRS, 500
+48/-0 HRS, AND 1000 +48/-0 HRS.
3.2.2.2.3 FINAL RF MEASUREMENTS - MEASURE AND RECORD VSWR @ 1 GHZ AND
ATTENUATION AT DC (0 GHZ) AND 1.0 GHZ.
3.2.3
GROUP C (QCI TESTING 4 SAMPLES APPROVED FROM GROUP A).
3.2.3.1
OF 1000 HOURS (1 HOURS ON, HOUR OFF). MEASURE AND RECORD ELECTRICALS AT 0,
250, 500, AND 1000 HOURS.
3.2.3.2
AFTER LOAD LIFE RF MEASUREMENTS – MEASURE AND RECORD VSWR AND ATTENUATION
AT 1 GHZ AT 25°C. TEST ACCEPTABLE LIMITS PER 4.2.1 OF TP-8965.
3.4
TEST DATA REQUIREMENTS:
3.4.1
TEST DATA REQUIRED FOR CUSTOMER - SEE PARAGRAPH 5.0 OF TP-8965.
3.4.2
DATA RETENTION - 24 MONTHS.
3.4.3
TEST SAMPLES REQUIRED FOR CUSTOMER - SEE PARAGRAPH 5.0 OF TP-8965.
4.0
PACKAGING:
STANDARD PACK PER MC0023. (SERIALIZED WAFFLE PACK)