E-36
Liquid Leakage Sensor Amplifier with Disconnection Detection Function
K7L-AT50D/-AT50D-S
Sensing Band
Note:
Specify length (in meter units) when ordering.
When cleaning with a mop, for example, do not make contact with the Sensing Band.
Sensing Band Sticker
Connecting the Sensing Band
Bending the Sensing Band
In order to change the direction of the Sensing Band, bend the Sens-
ing Band in one or two places where the core is not exposed.
Note:
Bend the Sensing Band approximately 4 cm (i.e., twice the dis-
tance between places where the core is exposed) away from
places where the Sticker is attached. If the Sensing Band is
bent at places further away than this, the Sensing Band may
come away from the surface.
Stripping and Connecting Terminals
1.
Cut into the Sensing Band approximately 4 to 6 cm in from the
end as shown in the diagram below.
2.
Strip away approximately the last 9 mm of the sheath to expose
the core (SUS line).
3.
To connect to the Terminal Block, push down the top of the termi-
nal with a screwdriver and insert the core from the side. (Refer to
Dimensions
on page 34.) More Sensing Bands can be connected
simply by wiring in an arch shape.
Note:
Check that the wiring is secure before using the K7L in applica-
tions.
Interval Between Stickers
When securing the Sensing Band with Stickers, attach the Stickers at
intervals of 20 to 30 cm in places where the core is not exposed.
Note: 1.
When using the F03-26PE (adhesive-tape model), be sure
to wipe all moisture, oil, and dust from the surface to which
the Sticker is to be attached. Failure to do so may result in
insufficient adhesion, and the Sticker may peel away from
the surface.
2.
When using the F03-26PEN (screw model), before installing
the Sensing Band, it is necessary to perform stud welding.
For details on the pitch of the studs, refer to the information
on the dimensions of Sensing Band Stickers.
Model
Appearance
Structure
Material
F03-16PE
Sheath: Polyethylene
Core: Stainless steel SUS316
Model
Appearance
Structure
F03-26PE/
F03-26PEN for
F03-16PE
Adhesive tape (see note)
Note:
The adhesive part is on the F03-26PE only.
F03-26PE
32
13
3.0
22
Material: Polyethylene
Note: 1.
The holes are in the F03-26PEN only.
2.
The adhesive part is on the F03-26PE only.
3.5 dia. (see note 1)
Adhesive tape (see note 2)
Cut section
Bent in 2 places
Bent in 1 place
9 mm
Insert
4 to 6 cm
Exposed
part of
core
F03-20
Terminal
Block
20 to 30 cm
Sensing
Band
Sticker