Advance Data Sheet
October 2000
Short-Loop Sine Wave Ringing SLIC
L9215A/G
4
Lucent Technologies Inc.
Features
I
On board balanced ringing generation
— 40 Vrms with a 1.414 crest factor provided to 5
REN ring load (1386
+ 40
μ
F) with 100
ring-
ing loop
— 40 Vrms with a 1.414 crest factor provided to 3
REN ring load (2310
+ 24
μ
F) with 250
ring-
ing loop
— No ring relay
— No bulk ring generator required
— 15 Hz to 70 Hz ring frequency supported
— Sine wave input-sine wave output
— PWM input-sine wave output
— Square wave input-trapezoidal output
I
Power supplies requirements
— V
CC
talk battery and ringing battery required
— No –5 V supply required
— No high-voltage positive supply required
I
Flexible Vcc options
— 5 V or 3.3 V V
CC
operation
— 5 V or 3.3 V V
CC
interchangeable and transparent
to users
I
Automatic battery switch
— Minimize off-hook power dissipation
I
Minimal external components required
I
11 operating states
— Forward active, V
BAT2
applied
— Polarity reversal active, V
BAT2
applied
— On-hook transmission, V
BAT1
applied
— On-hook transmission polarity reversal, V
BAT1
applied
— PPM active forward active, V
BAT2
applied
— PPM active polarity reversal active, V
BAT2
applied
— PPM active on-hook transmission, V
BAT1
applied
— PPM active on-hook transmission polarity rever-
sal, V
BAT1
applied
— Scan
— Forward disconnect
— Ring mode
I
Unlatched parallel data control interface
I
Ultralow SLIC power
— Scan 37 mW (V
CC
= 5 V)
— Forward/reverse active 54 mW (V
CC
= 5 V)
— Scan 27 mW (V
CC
= 3.3 V)
— Forward/reverse active 41 mW (V
CC
= 3.3 V)
I
Supervision
— Loop start, fixed threshold with hysteresis
— Ring trip, single-pole ring trip filtering, fixed thresh-
old as a function of battery voltage
— Common-mode current for ground key applica-
tions, user-adjustable threshold
I
Adjustable current limit
— 10 mA to 70 mA programming range
I
Overhead voltage
— Adjustable in active mode
— Clamped <51 V in scan mode
I
Thermal shutdown protection with hysteresis
I
Longitudinal balance
— ETSI/ITU-T balance
—
Telcordia
Technologies
TA-909 balance
I
Meter pulse compatible
— Dedicated meter pulse signal input
— On-hook transmission of PPM
I
ac interface
— Two SLIC gain options to minimize external com-
ponents required for interface to first- or third-gen-
eration codecs
— Sufficient dynamic range for direct coupling to
codec output
I
32-pin PLCC package
I
90 V CBIC-S technology
Description
The L9215 is designed to provide battery feed, ringing,
and supervision functions on short plain old telephone
service (POTS) loops. Supported loop length is 100
to 250
of wiring resistance plus handset or ringing
load. This device is designed for ultralow power in all
operating states.
The L9215 offers 11 operating states. The device
assumes uses of a lower-voltage talk battery, a higher-
voltage ringing battery, and a V
CC
supply.
The L9215 requires only a positive V
CC
supply. No
–5 V supply is needed. The L9215 can operate with a
V
CC
of either 5 V or 3.3 V, allowing for greater user flex-
ibility. The choice of V
CC
voltage is transparent to the
user; the device will function with either supply voltage
connected.
Two batteries are used:
1. A high-voltage ring battery (V
BAT1
).
V
BAT1
is a maximum –75 V. V
BAT1
is used for power
ring signal amplification and for scan and on-hook
transmission modes. This supply is current limited
to approximately the maximum power ringing cur-
rent, typically 50 mA.
2. A lower-voltage talk battery (V
BAT2
).
V
BAT2
is used for active mode powering.