General Purpose Relays
2
SCHRACK
Datasheet
Rev. HC1
Issued 2008/03
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
Miniature Relay PT (Continued)
Coil data
Rated coil voltage range DC coil
6...220 VDC
AC coil
6...230 VAC
Coil power DC coil
0.75 mW
AC coil
1.0 VA
Operative range DC coil, AC-coil 50Hz
2
AC coil 60 Hz at 70°C, % of Urtd
90..110%
Coil versions, DC-coil
Coil code
Rated
Operate
Release
Coil
Rated coil opt. LED
STD LED
LED+
voltage
resistance
power
bipolar
PD*
VDC
Ohm
mW
006
L06
LA6
6
4.5
0.6
48+10%
750
3.5
012
L12
LB2
12
9.0
1.2
192+10%
750
10
024
L24
LC4
24
18.0
2.4
777+10%
741
18
048
L48
LE8
48
36.0
4.8
3072+10%
750
38
060
L60
LG0
60
45.0
6.0
4845+12%
743
56
110
M10
MB0
110
82.5
11.0
16133+15%
750
96.5
220
N20
NC0
220
165.0
22.0
64533+15%
750
202.5
All figures are given for coil without preenergization, at ambient temperature +23°C
*) Protection diode PD; standard polarity: +A1 / -A2
Coil versions, AC-coil 50/60 Hz
Coil code
Rated
Operate
Release
Coil
Rated coil
STD
LED
voltage
resistance
power
50/60Hz
VAC
Ohm
VA
506
R06
6
4.8/5.4
1.8
11+10%
1.0/0.85
512
R12
12
9.6/10.8
3.6
48+10%
1.0/0.85
524
R24
24
19.2/21.6
7.2
192+
+10%
1.0/0.79
548
R48
48
38.4/43.2
14.4
777+10%
1.0/0.87
560
R60
60
48.0/54.0
18.0
1306+10%
1.0/0.87
615
S15
115
92.0/103.5
34.5
4845+12%
1.0/0.86
730
T30
230
184.0/207.0
69.0
19465+
+15%
1.0/0.90
All figures are given for coil without preenergization, at ambient temperature +23°C
Insulation
PT2
PT3
PT5
Dielectric strength coil-contact circuit
2500 Vrms
open contact circuit
1200 Vrms
adjacent contact circuits
2500 Vrms
2000 Vrms
Clearance / creepage coil-contact circuit
W 4/4 mm
adjacent contact circuits W 3.5/9.5 mm W 2.6/3.5 mm W 1.8/3.5 mm
Material group of insulation parts
W IIIa
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
basic
open contact circuit
functional
adjacent contact circuits
basic
functional
Rated insulation voltage
250 V
Pollution degree
2
Rated voltage system
240/400 V
240 V
Overvoltage category
III
Other data
RoHS - Directive 2002/95/EC
compliant
Ambient temperature range
-40...+70°C
Operate time
15 ms
Release time without / with protection diode
10 / 18 ms
Bounce time NO / NC contact
5 ms
Vibration resistance (function) NO / NC contact
7/4 g
Shock resistance (function) NO / NC contact
20/5 g
Category of protection
RTII- flux proof
Mounting distance
0 mm, dense packing
Resistance to soldering heat
270°C / 10s
Relay weight
30 g
Packaging unit
10/250 pcs