Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302
Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com
10
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input 12 Vdc /25 A Output, 1/4 Brick
Converter
March 27, 2009
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Remote Sense
This module has remote sense compensation feature. It can minimize the effects of resistance between
module’s output and load in system layout and facilitates accurate voltage regulation at load terminals or
other selected point.
1. The remote sense lines carries very little current and hence do not require a large cross-sectional area.
2. This module compensates for a maximum drop of 5% of the nominal output voltage.
3. If the unit is already trimmed up, the available remote sense compensation range should be
correspondingly reduced. The total voltage increased by trim and remote sense should not exceed 5%
of the nominal output voltage.
4. When using remote sense compensation, all the resistance, parasitic inductance and capacitance of the
system are incorporated within the feedback loop of this module. It can make an effect on the module's
compensation, affecting the stability and dynamic response.
A 0.1uF ceramic capacitor can be
connected at the point of load to de-couple noise on the sense wires.
5. Recommend the connection of remote sense compensation as below figure. There are a resistor RS+
(30.1 ohm) from Vo+ to Sense+ and a resistor RS- (30.1 ohm)) from Vo- to Sense- inside of this module.
6. If not using remote sense compensation, please connect sense directly to output at module's pin, that is,
connect sense+ to Vo+ and sense- to Vo- at module's pin, the shorter the better. See below figure.
Sense+
Sense-
R
S
-
V o-
Vo+
R
S
+
Load
Sense+
Sense-
R
S
-
Vo-
V o+
R
S
+
Load