Rockwell Automation
4-19
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
4
Product Selection
With 3 Main Contacts
Voltage Suffix Codes for AC Control
Voltage Suffix Codes for DC Control
( ) Control voltages in parentheses: No inventory
AC-1
(40°C)
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
Positively Guided
Aux. contact per Contactor
Cat. No.
PQ
[kW]
[A]
230 V
400 / 415 V
500 V
690 V
230 V
400 / 415 V
500 V
690 V
32
3
4
11.5
9
7
5
05
104S-C09
012C
1
05
104S-C09
010C
32
4
5.5
14.5
12
10
7
05
104S-C12
012C
05
104S-C12
010C
32
5.5
7.5
20
16 / 15
13
9.3
05
104S-C16
012C
05
104S-C16
010C
32
7.5
11
10
24
23 / 22
18
12
05
104S-C23
012C
05
104S-C23
010C
50
10
15
34
30 / 29
24
17
04
104S-C30
010C
04
104S-C30
008C
50
11
18.5
37
37 / 36
30
20
04
104S-C37
010C
04
104S-C37
008C
85
13
22
42
43 / 41
34
25
04
104S-C43
010C
04
104S-C43
008C
100
18.5
30
62
60 / 58
45
34
04
104S-C60
010C
04
104S-C60
008C
100
22
37
70
72 / 69
56
42
04
104S-C72
010C
04
104S-C72
008C
100
25
45
85
85 / 82
67
49
04
104S-C85
010C
04
104S-C85
008C
100S-C. 104S-C
[V]
122432364248
100
100-
110
120
127
200
200-
220
200-
230
208-
240
50 Hz
(R)
(K)
(V)
(W)
(X)
(Y)
(KP)
—
(D)
(P)
(S)
(KG)
—
60 Hz
(Q)
(J)
—
(V)
—
(X)
—
(KP)
—
(D)
—
(KG)
—
(L)
50/60 Hz
—
KJ
—
KY
(KP)
—
KD
—
(KG)
—
(KL)
—
[V]
220-
230
230-
240
277
347
380
380-
400
400-
415
440
480
500
550
600
50 Hz
(F)
—
(VA)
(T)
—
(N)
—
(G)
(B)
—
(M)
(C)
—
60 Hz
—
(A)
(T)
(I)
(E)
—
(N)
(B)
—
(C)
50/60 Hz
—
KF
—
(KA)
—
KN
—
(KB)
—
100S-C09…C43, 104S-C09…C43
[V] 9
12
24
36
48
60
64
72
80
110
115
125
220
230
250
DC
(ZR) (ZQ)
ZJ
(ZW) (ZY)
(ZZ)
(ZB) (ZG) (ZE)
ZD
(ZP)
(ZS)
(ZA)
(ZF)
(ZT)
with diode protection circuit DC
—
DJ
—
100S-C60…C85, 104S-C60…C85
DC
—
with diode protection circuit DC
(DR) (DQ)
DJ
(DW) (DY) (DZ) (DB) (DG) (DE)
DD
(DP) (DS) (DA) (DF) (DT)
Price Adder for:
Type
Available Control Voltages
No Surcharge
Special control voltages
100S-C. 104S-C
12…600 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC
> 20 pieces
Power ratings: Preferred values according to IEC 60072-1
With mechanical and electrical locking 100-MCA02
Extended operating limits 0.65…1.3 x Us
Extended operating limits 0.7…1.25 x Us
Reversing-Safety Contactors
AC / DC control
3 main contacts, coil connections above
Positively guided contacts acc. to IEC 947-5-1
Mechanically coupled Contactor and Auxiliary contact block
Protection against unintended actuation
Auxiliary contacts are electronically compatible according
to DIN 19240
Mechanical / Electrical interlock included
Wiring set for main pole interconnection included
Specifications - Page 4-36