參數(shù)資料
型號: 100-M12NZD243S
英文描述: CONTACTOR 12A 24VDC
中文描述: 接觸器12A條24Vdc的
文件頁數(shù): 67/78頁
文件大小: 4808K
代理商: 100-M12NZD243S
Rockwell Automation
4-7
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
4
Overview - Bulletin CAB6
CAB6-85…170
CAB6-210…420
110
mm
Bulletin CAB6 Contactors with electronically controlled Coil Mechanism
Bulletin CAB6 contactors are equipped with electronically controlled coil mechanisms and integrated interface starting from size
CAB6-105-EI. Size CAB6-85 is equipped with conventional coils and sizes CAB6-105 and CAB6-140 can be equipped with either
conventional or electronic coils. Contactors with electronic coils are characterised by the -El suffix. By offering control options, a
multitude of possibilities are at the user's disposal:
Defined on- and off- points
Electronic control guarantees defined points of switching on and off, thus pre-
venting chatter and damage to the contactor.
Environmentally friendly
Construction and contact materials do not contain cadmium, asbestos or PCBs
and can be recycled at the end of the contactor life. Most plastic parts are char-
acterised according to DIN 54840.
Frame terminal blocks
Go safe! Contact protection is fulfilled by attachable terminal covers according
to DIN VDE 0106 and VBG 4. By using framework terminal blocks the contactor
automatically becomes finger-safe per IP20.
Compact dimensions
New, compact construction solutions and the application of electronics substan-
tially reduces the dimensions. Two housing sizes cover the entire range from
85...420 A (AC-3). Simple and efficient wiring is ensured by the identical con-
nection height of the main pole on both housing sizes.
Bulletin CAB6 contactors can be mechanically interlocked, without needing ad-
ditional mounting space.
Integrated interface
The factory supplied CAB6-EI range features an interface module that can be
activated and deactivated via an externally accessible jumper unit. With the
interface, the contactor can be addressed directly by a 24 V DC signal from a
programmable logic controller. The max. allowable current of the interface is 15
mA (DIN VDE 19240). The Interface input is separated from the coil circuit by
photoelectric.
Protective circuit included
All EI-type contactors have a protective circuit as standard.
Low pick-up and holding power
When compared with conventional contactors, the current requirement is sub-
stantially lowered by the construction of the contactor, particularly via the elec-
tronic control.
Wide voltage range
Despite the wide voltage range (e.g., 208...277 V AC) the min./max. values of
the IEC tolerances are kept between -0.85 and +1.1.
相關PDF資料
PDF描述
100313DC Quad Peripheral Driver
100313DCQR Quad Peripheral Driver
100313DM Quad Peripheral Driver
100313DMQB Quad Peripheral Driver
100313FCQR Quad Peripheral Driver
相關代理商/技術參數(shù)
參數(shù)描述
100M1N2 制造商:unknown 功能描述:
100M35DC 制造商: 功能描述: 制造商:undefined 功能描述:
100M-A21C 制造商:OSRAM SYLVANIA 功能描述:100MA21C
100MAT SIZE 6 制造商:BM POLYCO 功能描述:MATRIX F GRIP 6 NYLON/FOAM
100ME100AX 制造商:SUN Electronic Industries Corporation 功能描述:Cap Aluminum 100uF 10V 20% (12.5 X 20mm) Radial 5mm 800mA 7000h 105 C