Absolute Maximum Ratings
(Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Above which the useful life may be impaired
Storage Temperature
Maximum Junction Temperature (T
J
)
Ceramic
Case Temperature under Bias (T
C
)
V
EE
Pin Potential to Ground Pin
Input Voltage (DC)
Output Current (DC Output HIGH)
65C to +150C
+175C
–55C to +125C
7.0V to +0.5V
V
CC
to +0.5V
50 mA
Operating Range (Note 2)
ESD (Note 3)
5.7V to 4.2V
≥
2000V
Recommended Operating
Conditions
Case Temperature (T
C
)
Military
Supply Voltage (V
EE
)
Note 2:
Absolute maximum ratings are those values beyond which the de-
vice may be damaged or have its useful life impaired. Functional operation
under these conditions is not implied.
Note 3:
ESD testing conforms to MIL-STD-883, Method 3015.
55C to +125C
5.7V to 4.2V
Military Version
DC Electrical Characteristics
V
EE
= 4.2V to 5.7V, V
CC
= V
CCA
= GND (Note 6)
Symbol
Parameter
V
OH
Output HIGH
Voltage
Min
1025
Typ
Max
870
Units
mV
T
C
Conditions
Notes
0C to
+125C
55C
0C to
+125C
55C
0C to
+125C
55C
V
IN
= V
IH(Max)
or V
IL(Min)
Loading with
50
to 2.0V
(Notes
4, 5, 6)
1085
1830
870
1620
mV
mV
V
OL
Output LOW
Voltage
1830
1035
1555
mV
mV
V
OHC
Output HIGH
Voltage
V
IN
= V
IH(Min)
or V
IL(Max)
Loading with
50
to 2.0V
1085
mV
(Notes
4, 5, 6)
V
OLC
Output LOW
Voltage
1610
mV
0C to
+125C
55C
1555
mV
DC Electrical Characteristics
V
EE
= 4.2V to 5.7V, V
CC
= V
CCA
= GND (Note 6)
Symbol
Parameter
V
DIFF
Input Voltage
Differential
V
CM
Common Mode
Voltage
V
IH
Single-Ended
Input High Voltage
V
IL
Single-Ended
Input Low Voltage
I
IH
Input HIGH Current
CLKIN, CLKIN
TCLK
CLKSEL
I
CBO
Input Leakage
Current
I
EE
Power Supply
Current, Normal
Min
150
Typ
Max
Units
mV
T
C
Conditions
Notes
55C to
+125C
55C to
+125C
55C to
+125C
55C to
+125C
55C to
+125C
Required for Full
Output Swing
(Notes 4, 5,
6)
V
CC
2.0
V
CC
0.5
V
(Notes 4, 5,
6)
1165
870
mV
Guaranteed HIGH Signal
for All Inputs
Guaranteed LOW Signal
for All Inputs
V
IN
= V
IH(Max)
(Notes 4, 5,
6, 7)
1830
1475
mV
(Notes 4, 5,
6, 7)
150
μA
(Notes 4, 5,
6)
450
380
μA
μA
μA
10
55C to
+125C
55C to
+125C
V
IN
= V
EE
(Notes 4, 5,
6)
80
25
mA
(Notes 4, 5,
6)
Note 4:
F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals 55C), then testing immediately
without allowing for the junction temperature to stabilize due to heat dissipation after power-up. This provides “cold start” specs which can be considered a worst case
condition at cold temperatures.
www.national.com