Board Mountable
DC-DC Converters
IMR 15 Series
Edition 5/5.2000
7/8
12
min. 5
1
50.8
20.32
15.24
Vo+
50.8
5.08
22.86
10.2 10.2
Vi–
Vi+
Vo–
09035
Measuring point of case temperature
TC
COM
Fig. 7
Case 2
× 2" for single and dual output
Weight: 70 g
Mechanical Data
Dimensions in mm. Tolerances
±0.3 mm unless otherwise specified.
European
Projection
12
min. 5
1
50.8
45.72
Vo2+
50.8
5.08
12.7
Vi– Vi+
Vo3-
09047
5 x 10.16
10.16
SD
COM Vo1+
Measuring point of case temperature
TC
Fig. 8
Case 2
× 2" for triple output types
Weight: 70 g
Safety and Installation Instructions
Installation Instruction
Installation of the DC-DC converters must strictly follow the
national safety regulations in compliance with the enclo-
sure, mounting, creepage, clearance, casualty, markings
and segregation requirements of the end-use application.
Connection to the system shall be made via a printed circuit
board according to:
Mechanical Data.
The units should be connected to a secondary circuit.
Check for hazardous voltages before altering any connec-
tions.
Ensure that a unit failure (e.g. by an internal short-circuit)
does not result in a hazardous condition. See also:
Safety
of operator accessible output circuit.
Standards and approvals
The units have been evaluated for:
Building in
Operational insulation input to output
The use in a pollution degree 2 environment
Connecting the input to a secondary circuit which is sub-
ject to a maximum transient rating of 500 V.
Isolation
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Input Fuse
To prevent excessive current flowing through the input sup-
ply line in case of a short-circuit across the converter input
an external fuse should be installed in a non earthed input
supply line. We recommend a fast acting fuse F5A for
12 IMR 15 types, F3.15A for 24 IMR 15 and F1.6A for
48 IMR 15 types.
Cleaning Agents
In order to avoid possible damage, any penetration of
cleaning fluids is to be prevented, since the power supplies
are not hermetically sealed.
Protection Degree
The protection degree of the DC-DC converters is IP 40.
Table 7: Electric strength test voltages, clearance and
creepage distances
Characteristic
Input to output
Unit
Electric strength
350
Vrms
test voltage 1 s
500
V DC
Coupling capacitance
≈400
pF
Isulation resistance
>1000
M