130-160MT..KB Series
Bulletin I27502 rev. A 05/03
www.irf.com
2
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage
Type number
Code
V
RRM
, maximum repetitive
peak reverse voltage
V
800
V
RSM
, maximum non-
repetitive peak rev. voltage
V
900
I
RRM
max.
@ T
max.
mA
80
100
120
140
160
1000
1200
1400
1600
1100
1300
1500
1700
130-160MT..KB
10
I
O
Maximum DC output current
@ Case temperature
130 (160)
85 (62)
160 (200)
85 (60)
A
°C
120° Rect conduction angle
I
FSM
Maximum peak, one-cycle forward,
1130
1430
A
t = 10ms
No voltage
non-repetitive surge current
1180
1500
t = 8.3ms
reapplied
950
1200
t = 10ms
100% V
RRM
reapplied
1000
1260
t = 8.3ms
Initial T
J
= T
J
max.
I
2
t
Maximum I
2
t for fusing
64000
10200
A
2
s
t = 10ms
No voltage
5800
9300
t = 8.3ms
reapplied
4500
7200
t = 10ms
100% V
RRM
reapplied
4100
6600
t = 8.3ms
I
2
√
t
Maximum I
2
√
t for fusing
64000
102000
A
2
√
s
t = 0.1 to 10ms, no voltage reapplied
V
F(TO)1
Low level value of threshold voltage
0.78
0.81
V
(16.7% x
π
x I
F(AV)
< I <
π
x I
F(AV)
), @ T
J
max.
(I >
π
x I
F(AV)
), @ T
J
max.
(16.7% x
π
x I
F(AV)
< I <
π
x I
F(AV)
), @ T
J
max.
(I >
π
x I
F(AV)
), @ T
J
max.
I
pk
= 200A, T
J
= 25°C, t
p
= 400μs single junction
V
F(TO)2
High level value of threshold voltage
0.99
1.04
r
f1
r
f2
V
FM
Low level value of forward slope resistance
4.59
3.52
m
High level value of forward slope resistance
4.17
3.13
Maximum forward voltage drop
1.63
1.49
V
V
INS
RMS isolation voltage
4000
4000
V
T
J
= 25°C, all terminal shorted
f = 50Hz, t = 1s
Parameter
130MT.KB 160MT.KB Units Conditions
Forward Conduction
Thermal and Mechanical Specifications
T
J
T
stg
Max. junction operating temperature range
-40 to 150
°C
Max. storage temperature range
-40 to 150
°C
R
thJC
Max. thermal resistance, junction to case
0.16
0.12
K/W
DC operation per module
0.93
0.73
DC operation per junction
0.18
0.15
120° Rect condunction angle per module
1.08
0.88
120° Rect condunction angle per junction
R
thCS
Max. thermal resistance, case to heatsink
0.03
K/W
Per module
Mounting surface smooth, flat and greased
T
Mounting torque ± 10%
to heatsink
4 to 6
Nm
to terminal
3 to 4
wt
Approximate weight
176
g
Parameter
130MT.KB 160MT.KB Units Conditions
A mounting compound is recommended and the
torque should be rechecked after a period of 3
hours to allow for the spread of the compound.
Lubricated threads.