2/70
DLI 2.5
DLI 2.5 LD PNP
DLI 2.5 LD NPN
DLD 2.5
6/65/49
7 mm/M 2,5/3,5 x 0,6
250 V/20 A/2,5 mm2
4 kV/3
0,4…0,7
1
0,5…4
0,5…2,5
A 3
20 A/2,5 mm2
(Q 2…10) 20
300 V/10 A/26…12 AWG
W
Cat. No. Qty.
131336
100
(w/o dekafix)
141136
10
(with dekafix)
157907
10
Type
Cat. No. Qty.
AP
131326
20
TSch 1
031916
100
StB 8.5* ( 2,3) 021570
50
PS 2.3
018040
20
Q 2
131250
50
Q 3
131260
50
Q 4
131270
50
Q 10
131310
20
Q 20
139980
20
QL 2
029720
100
VH 3.8
134580
100
WT 4
134106
100
SF 10
033240 1000
SG 10
033250 1000
ADP
048540
–
HP 4
048586
20
FW 6
046866
–
FS 6
046876
–
Dimensions
Width / length / height (mm)
with TS 35 x 7,5 W
Insulation stripping length/clamping screw/screwdriver blade
VDE rated data, VDE 0611 Part 1/8.92/IEC 947-7-1
Rated voltage / current / cross-section
Rated impulse voltage / pollution severity
Further technical data
Tightening torque range
Nm
Torque setting with DMS 2 electric screwdriver
Clampable conductor
solid H07V-U
mm2
stranded H07V-R
mm2
flexible H07V-K
mm2
flexible H07V-K and AEH DIN 46 228/1
mm2
Plug gauge according to 947-1
Size
Continuous current of terminal block for conductor size
Continuous current rating of cross-connection
2…5-pole
A
Continuous current rating of cross-connection 6…10-pole
A
UL / CSA rated data
Voltage / current / conductor size
UL
Voltage / current / conductor size
CSA
Ordering data
Standard
With diode 1N4007
With LED rot (5…30 V)
With LED grün (5…30 V)
With LED and Diode 1N4007
Block of 101)
Fuse inserts
End plate/partition
AP-DLI
AP-DLD
Teil-AP
TSch 1
(thickness 1.5 mm)
Test plug/socket
PS 2.3
StB 8.5
Cross-connection
Q 3
Group marking
WT 4
Cover
HP 4
Marking tags
Print
Consecutive horizontal
Consecutive vertical
For cross-connections for more than
20 terminal blocks, replace VH with
VH 3.8 (134580) without internal
thread
6/65/49
7 mm/M 2,5/3,5 x 0,6
5–30 V-/20 A/2,5 mm2
0,8 kV/3
0,4…0,7
1
0,5…4
0,5…2,5
A 3
20 A/2,5 mm2
(Q 2…10) 20
300 V/10 A/26…12 AWG
–
W
Cat. No. Qty.
157851
100
157852
100
(LED red)
157853
10
(LED green)
157854
10
Type
Cat. No. Qty.
AP
131326
20
TSch 1
031916
100
Q 2
131250
50
Q 3
131260
50
Q 4
131270
50
Q 10
131310
20
Q 20
139980
20
QL 2
029720
100
VH 3.8
134580
100
WT 4
134106
100
SF 10
033240 1000
SG 10
033250 1000
ADP
048540
–
HP 4
048586
20
FW 6
046866
–
FS 6
046876
–
6/65/49
7 mm/M 2,5/3,5 x 0,6
5–30 V-/20 A/2,5 mm2
0,8 kV/3
0,4…0,7
1
0,5…4
0,5…2,5
A 3
20 A/2,5 mm2
(Q 2…10) 20
300 V/10 A/26…12 AWG
–
W
Best.-Nr . Qty.
157855
100
157856
100
Type
Cat. No. Qty.
AP
131326
20
TSch 1
031916
100
Q 2
131250
50
Q 3
131260
50
Q 4
131270
50
Q 10
131310
20
Q 20
139980
20
QL 2
029720
100
VH 3.8
134580
100
WT 4
134106
100
SF 10
033240 1000
SG 10
033250 1000
ADP
048540
–
HP 4
048586
20
FW 6
046866
–
FS 6
046876
–
6/82/49
7 mm/M 2,5/3,5 x 0,6
250 V/24 A/2,5 mm2
4 kV/3
0,4…0,7
1
0,5…4
0,5…2,5
A 3
(Q 2…10) 20
300 V/10 A/26…12 AWG
W
Cat. No. Qty.
131706
50
Type
Cat. No. Qty.
AP
131766
20
AP (part-AP)
138186
20
TSch 1
031916
100
StB 8.5* ( 2,3) 021570
50
PS 2.3
018040
20
Q 2
131250
50
Q 3
131260
50
Q 4
131270
50
Q 10
131310
20
Q 20
139980
20
QL 2
029720
100
VH 3.8
134580
100
WT 4
134106
100
SF 10
033240 1000
SG 10
033250 1000
ADP
048540
–
HP 4
048586
20
FW 6
046866
–
FS 6
046876
–
For further accessories see section 3, further marking material see section 8
WWWW
Feed-through terminals
for initiators and actuators
1) DLI 2.5/35/10 = Block of 10 with built-in cross-connections * Only in upper busbar