Product catalogue | PCB connection systems | PCB plug-in connectors | Pitch 5.00 / 5.08 mm (0.197 / 0.200 inch) |
Socket connectors, tension clamp connection, pitch 5.00/5.08 | BLZP 5.00/5.08/180 | BLZP 5.08/180LR SN
- 2 -
Connectable conductors
Clamping range, min.
0.13 mm
Clamping range, max.
4 mm
AWG, min.
26
AWG, max.
12
Solid, min. H05(07) V-U
0.2 mm
Solid, max. H05(07) V-U
4 mm
Flexible, min. H05(07) V-K
0.2 mm
Flexible, max. H05(07) V-K
4 mm
With wire end ferrule, acc. to DIN 46 228/1, min.
0.2 mm
With wire end ferrule, acc. to DIN 46 228/1, max. 4 mm
w. plastic collar ferrule, DIN 46228 pt 4, min.
0.2 mm
w. plastic collar ferrule, DIN 46228 pt 4, max.
2.5 mm
Gauge to EN 60999 a x b;
2.8 mm x 2.4 mm
DIN IEC rating data
Rated current, min. No. pins (Tu=20°C)
19 A
Rated current, max. No. pins (Tu=20°C)
15.5 A
Rated current, min. No. pins(Tu=40°C)
16 A
Rated current, max. No. pins (Tu=40°C)
13 A
Rated voltage for overvoltage class/pollution
severity II/2
400 V
Rated voltage for overvoltage class/pollution
severity III/2
320 V
Rated voltage for overvoltage class/pollution
severity III/3
250 V
Rated impulse withstand voltage for overvoltage
class/pollution severity II/2
4 kV
Rated impulse withstand voltage for overvoltage
class/pollution severity III/2
4 kV
Rated impulse withstand voltage for overvoltage
class/pollution severity III/3
4 kV
Short-time withstand current resistance
3 x 1s with 120 A
CSA rating data
Rated voltage (Use group C)
50 V
Rated voltage (Use group D)
300 V
Rated current (Use group D)
10 A
AWG conductor (field wiring), min.
26
AWG conductor (field wiring), max.
12
UL 1059 rating data
Rated voltage (Use group C)
50 V
Rated voltage (Use group D)
300 V
Rated current (Use group D)
10 A
AWG conductor, min.
26
AWG conductor, max.
12