參數(shù)資料
型號(hào): 19665
廠商: Desco
文件頁(yè)數(shù): 2/4頁(yè)
文件大?。?/td> 0K
描述: MONITOR DUAL WIRE CONTINOUS 120V
標(biāo)準(zhǔn)包裝: 1
類型: 工作站監(jiān)視器
使用: 工作面(2),腕帶(2)監(jiān)視
特點(diǎn): 連續(xù)監(jiān)視,雙芯系統(tǒng)
電源類型: AC 適配器
包括: AC 適配器,線纜,軟線,遙控器
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Website: Desco.com
TB-3019 Page 2 of 4
2014 DESCO INDUSTRIES, INC.
Employee Owned
F. Operator 2 Remote Jack: Connect to the black operator
remote cable.
G. Operator 1 Remote Jack: Connect to the white operator
remote cable.
H. Monitored Mat 1 Terminal: Monitors a worksurface mat
for proper dissipative resistance and static charges. Connect
the white mat monitor cord here.
I. Ground Terminal: Common ground point for the monitor.
Connect to the green and yellow monitor ground cord.
J. Monitored Mat 2 Terminal: Monitors a worksurface mat
for proper dissipative resistance and static charges. Connect
the black monitor cord here.
K. Data Output: To be used with the EMIT 50476 Smart
Hub and EMIT SIM Software for automated record keeping
of the monitor’s performance. Click here to learn more about
the EMIT SIM Software.
L. Alarm Audible Adjustment: Turn the trimpot
counter-clockwise to increase the audible alarm volume and
clockwise to decrease it.
Installation
1. Determine the mounting location of the Dual-Wire
Dual-Operator Monitor. The front panel should be visible
to both operators.
2. Determine the mounting locations of the operator
remotes. Be sure to install the remotes at a distance
that enables the 10 foot leads to reach the back of the
monitor.
3. Install tinned wire ends of the mat cords to their
appropriate screw terminal block located at the back of
the monitor.
4. Attach the worksurface mats to ground using the green
mat ground cord. Install the ring terminal end of the
cord to an appropriate ground point. Attach the
snaps terminals to the snaps on the worksurface mat.
5. Install the tinned wire end of the green and yellow
moniitor ground cord to the ground terminal located
at the back of the monitor. Install its ring terminal to an
appropriate ground point. Be sure to use a different
ground point than the one used for the mats. The face
plate screw of a grounded AC wall outlet may provide a
convenient connection point.
6. Route the mat cords from the back of the monitor to
the snaps on worksurface mats. The white cord is for
worksurface mat #1. The black cord is for worksurface
mat #2.
7. Insert the operator remote cables into their appropriate
jacks located at the back of the monitor. The white cable
is for operator #1. The black cable is for operator #2.
8. Connect the power adapter to the power jack located
at the back of the monitor. Plug the power adapter into
a proper AC power outlet. The monitor is now powered.
Operation
1. Monitoring of the operators will remain in the STANDBY
condition until a wrist cord is plugged into the operator
remote. STANDBY mode is indicated by a blinking
yellow operator LED.
2. Plug a wrist strap cord, not attached to the wristband,
into the monitored jack labeled WRIST STRAP
MONITOR located on the remote. This automatically
activates the selected operator channel. The
corresponding operator LED should illuminate red and
the alarm should sound on the monitor.
3. Remove the charges from your body by making contact
with a properly grounded ESD worksurface.
4. Snap the cord to the wristband, and fit it snugly onto
your wrist. This should silence the audible alarm and
cause the corresponding operator LED to switch from
red to green. If this does not happen, examine the wrist
cord for continuity or damage and your wrist band to
ensure that it is securely fit. If you have dry skin,
apply an approved dissipative hand lotion such as
5. The AUX GND jack located on the operator remote
is a grounded and unmonitored connection for guests. It
must be used with a banana plug wrist cord and
single-wire wristband.
NOTE: Worksurface must have a conductive layer such as
Dual Layer Rubber or Dissipative 3-Layer Vinyl or Micastat
Dissipative Laminate with conductive buried layers. EMIT
Continuous Monitors are not recommended for use with
homogeneous matting.
10mm snap needs to pierce
and clinch bottom side of
mat. Snap needs to be at
least 12" apart or 72" max.
10mm snap needs to pierce
and clinch bottom side of
mat. Snap needs to be at
least 12" apart or 72" max.
OPERATOR 1
WORKSURFACE
OPERATOR 2
WORKSURFACE
10mm PUSH &
CLINCH SNAP
10mm PUSH &
CLINCH SNAP
BENCH
GROUND
MAT 1 WIRING
WHITE CABLE
MAT 2 WIRING
BLACK CABLE
WRIST
STRAP
MONITOR
WRIST
STRAP
MONITOR
ELECTRIC
GROUND
OPERATOR 2
REMOTE JACK
BLACK CABLE
OPERATOR 2
REMOTE JACK
WHITE CABLE
Screw allows ground cord to
be bolted to mat; keeps cord
from disconnecting.
Figure 3. Installing the Dual-Wire Dual-Operator
Programmable Monitor
or
相關(guān)PDF資料
PDF描述
19780 KIT METER RES DIG TEMP/HUMIDITY
19784 TEST KIT SURFACE RESISTANCE
19851 WRIST STRAP DUAL ASSY 12' CORD
19859 WRISTSTRAP DUAL ASSY MTL EXP 4MM
19866 COIL CORD DUAL SNAPONE 4MM 18'
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
1966-5 制造商:VIDEK 功能描述:EXTENSION LEAD CAT6 UTP BEIGE 5M 制造商:VIDEK 功能描述:EXTENSION LEAD, CAT6 UTP, BEIGE, 5M 制造商:VIDEK 功能描述:PATCH CABLE, CAT 6, BEIGE, 5M; Cable Length - Imperial:16.4ft; Cable Length - Metric:5m; Connector Type A:RJ45 Plug; Connector Type B:RJ45 Jack; Jacket Color:Beige; Cable Assembly Type:Network ;RoHS Compliant: Yes
1-966504-0 制造商:TE Connectivity 功能描述:DUOPLUG2,5BUST6X10P - Bulk
1-966504-4 制造商:TE Connectivity 功能描述:DUOPLUG2,5BUST13X4P - Bulk
1-966504-5 制造商:TE Connectivity 功能描述:DUOPLUG2,5BUST11X5P - Bulk
1-966504-6 制造商:TE Connectivity 功能描述:DUOPLUG2,5BUST10X6P - Bulk