23
Nominal voltage U
N
(V)
8
12
24
48
110
125
230
240
Resistance R
(
)
3.5
7
27
105
600
700
2500
2700
Current consumption
I
at U
N
(50 Hz)
(mA)
700
450
210
110
45
42
23.5
22
Resistance R
(
)
—
27
105
440
2330
—
—
—
Current consumption
I
at U
N
(mA)
—
440
230
110
47
—
—
—
AC - DC VERSION DATA (R values relate to +20
°
C. Tolerance of R and
I
values:
±
10%.)
AC
DC
VERSIONS:
AC - alternating current 50
÷
60 Hz
DC - direct current
COIL
SPECIFICATION
NOMINAL VOLTAGE U
N
RATED POWER CONSUMPTION
OPERATING RANGE
MAXIMUM IMPULSE DURATION
AC: 8 - 12 - 24 - 48 - 110 - 125 - 230 - 240 V
DC: 12 - 24 - 48 - 60 - 110 V
AC: 5.5 VA
DC: 5 W
AC (50 Hz): (0.85
÷
1.1) U
N
AC (60 Hz): (0.9
÷
1.1) U
N
DC: (0.9
÷
1.1) U
N
ACCORDING TO IEC 669
CONTACT
SPECIFICATION
RATED CURRENT
MAXIMUM PEAK CURRENT
RATED VOLTAGE
MAXIMUM SWITCHING VOLTAGE
NOMINAL RATE
AC1:
compensated fluorescent lamps:
uncompensated fluorescent lamps:
incandescence lamps::
halogen lamps:
ELECTRICAL LIFE
STANDARD CONTACT MATERIAL
16 A
30 A
250 V AC
400V AC
4000 VA
750 W
1000 W
2000 W
2000 W
≥
100 · 10
3
operations
Ag Ni
230 V AC
230 V AC
230 V AC
230 V AC
between coil and contacts
between open contacts
between adjacent contacts
≥
10 · 10
3
M
tested at:
leakage current
≤
30 mA for
1 min at 50 Hz
TECHNICAL DATA
INSULATION RESISTANCE
MAXIMUM SWITCHING
FREQUENCY
AMBIENT TEMPERATURE
MECHANICAL LIFE
PROTECTION CATEGORY
DIELECTRIC STRENGTH
3500 V
2000 V
2000 V
- without load: 3600 operations/h
- at rated load: 900 operations/h
– 40 to 40
°
C
300 · 10
3
operations
IP 20
If the coil works for a prolonged period of time, adaquate ventilation of the relays must be
provided, for example leaving a gap of abent 9mm between them.