Part No. HA026158 Issue 2
2132
OP1
OP2
Electrical connections
2132
2116
Specifications
Supply voltage:
85-264Vac, 48-62Hz, or 20-29Vac/dc, 5watts max
Operating ambients:
0-55°C, 5-95%RH non-condensing
Output ratings:
Logic: 9Vdc, 12mA (non-isolated)
(Can also be used as alarm acknowledge, keylock
and timer start/stop input)
Relay: 2A, 264V ac resistive
Calibration accuracy:
± 1°C or ± 0.25% of reading whichever is greater
Cold junction compensation:
> 15 to 1 rejection of ambient temperature change
Input filtering:
Off to 999.9 seconds
2116
OP1
OP2
48 mm
(1.89in)
48 mm (1.89in)
103 mm (4.01in)
Panel cut-out
- 0.0
+ 0.6
45 x 45 mm
Panel cut-out
- 0.0
+ 0.3
22.2 x 45 mm
103 mm (4.01in)
48 mm (1.89in)
24 mm
(0.95in)
Dimensions
2132
2116
Line
Neutral
85-264Vac
(Relay)
Outpt 2
T/C
PT100
1A
+
1B
mA Input
Sensor inputs
OR
-
V-
V+
AB
AA
N
L
2.49
External
Relay
Module
Output 1
(Logic)
Solid
State
Relay
1A
1B
24
24
20-29Vac/dc
Low voltage supply
Timer range:
0-9999 minutes
Setpoint rate limit adjustment:
0-999.9 least significant display unit per minute.
Adjustable hysteresis
Alarm configuration:
High, low, deviation band, deviation high and low
EMC standards:
Meets generic emissions standard EN50081-2 and
immunity standard EN50082-2 for industrial
environments
Safety standard:
Meets EN61010, installation category II. Pollution
degree 2
Atmospheres:
Not suitable for use above 2000m or in explosive or
corrosive atmospheres
Line
85-264Vac
Neutral
Output 2
(Relay)
L
N
AB
V+
V-
T/C
PT100
Output 1
(Logic)
AA
1A
1B
+
-
mA Input
Sensor
inputs
External
Relay
Module
2.49
Solid
State
Relay
OR
1A
1B
24
24
20-29Vac/dc
Low voltage supply
- 0.0
1.77 x 1.77in
- 0.00
+ 0.02
0.88 x 1.77in
- 0.0
+ 0.01
- 0.0
+ 0.02
Copyright Eurotherm Controls Limited 1997
All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Controls Limited. Every effort has been
taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our products which could, without notice, result in amendments or
omissions to this specification. We cannot accept responsibility for damage, injury, loss or expenses resulting therefrom.
EUROTHERM CONTROLS LIMITED
http://www.eurotherm.co.uk
UK SALES OFFICE
Eurotherm Controls Limited. Faraday Close, Durrington, Worthing, West Sussex BN13 3PL
Telephone Sales: (01903) 695888; Technical: (01903) 695777; Service: (01903) 695444
Fax (01903) 695666
Sales and support in over 30 countries worldwide
Enquiries/orders to: Eurotherm Controls Limited Export Dept., Faraday Close, Durrington, Worthing. West Sussex BN13 3PL.
Telephone (01903) 268500, Fax (01903) 265982
VH
85-264Vac
VL
20-29V dc or ac
Manual
XXX
No manual
ENG
English
FRA
French
GER
German
NED
Dutch
SPA
Spanish
SWE
Swedish
ITA
Italian
Output 1 (Logic)
Function
CC
PIDController
NF
ON/Off Controller
TC
PID Controller + Timer
TN
ON/Off Contr’ + Timer
Sensor Input
Setpoint Min/Max
Units
C
F
K
X
°C
°F
Kelvin
Linear input
Ordering Code
External Relay Module
XX
Not fitted
R7
Fitted (Operated by the
logic output)
Input Adaptor
XX
Not fitted
V1
0-10Vdc
A1
0-20mA or 4-20mA
0.1% current sense
resistor (2.49
)
Supply Voltage
Model
Number
Function
Supply
Voltage
Manual
Output 1
(Logic)
Output 2
(Relay)
Sensor
Input
note 2
Setpoint
Min.
note 2
Setpoint
Max.
Units
Ext. Relay
Module
Input
Adaptor
XX
No function
Logic output
LH
Heating
LC
Cooling
M1
PDS heater break
detect (note 1)
FH
High alarm 1
FL
Low alarm 1
DB
Dev. band alarm 1
DL
Dev. low larm 1
DH
Dev. high alarm 1
NW
New alarm
Logic input
AC
Alarm ack/reset
KL
Keylock
TM
Timer Off/On
Thermocouples
J
Type J
K
Type K
T
Type T
L
Type L
N
Type N
R
Type R
S
Type S
B
Type B
P
Platinell II
Resistance thermometer
Z
Pt100
Custom downloaded inputs
C
Type C - W5%Re/W26%Re
(default custom sensor)
D
Type D - W3%Re/W25%Re
E
E Thermocouple
1
Ni/Ni18%Mo
2
Pt20%Rh/Pt40%Rh
3
W/W26%Re (Englehard)
4
W/W26%Re (Hoskins)
5
W5%Re/W26%Re (Englehard)
6
W5%Re/W26%Re (Bucose)
7
Pt10%Rh/Pt40%Rh
8
Exegen K80 I.R. pyrometer
Process inputs (linear)
M
-9.99 to +80mV
Y
0 to 20mA (note 3)
A
4 to 20mA (note 3)
V
0 to 10Vdc (input adapter required)
Min °C
-210 to 1200
-200 to 1372
-200 to
-200
to
-200 to 1300
-50 to 1768
-50 to 1768
0 to 1820
0 to 1369
Max
400
900
-200 to
850
0 to 2319
0 to 2399
-200 to
0 to 1399
0 to 1870
0 to 2000
0 to 2010
10 to 2300
0 to 2000
200 to 1800
-45 to
999
650
-1999 to 9999
-1999 to 9999
-1999 to 9999
-1999 to 9999
Note 2. Setpoint min and
max: include the decimal
position required in the
display value; up to one for
temperature input, up to two
for process inputs.
Note 3. An external 1%
current sense resistor is
supplied as standard. If
greater accuracy is required
specify ‘A1’ in the Input
Adaptor field.
2132
48 x 24mm unit
2116
48 x 48mm unit
Model Number
Output 2 (Relay)
XX
No function
RH
Heating
RC
Cooling
FH
High alarm 2
FL
Low alarm 2
AL
High alarm 2 & low
alarm 3
DB
Dev. band alarm 2
DL
Dev. low larm 2
DH
Dev. high alarm 2
NW
New alarm
Note 1. PDS heater
break detect will transmit
the power demand to a
TE10S Solid State Relay
and read beck a heater
break alarm.