1
06-2011, Rev. 0611
www.te.com
2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
n
Noise level below 50dBA
n
Pin assignment according to ISO 7588 part 3
n
Plug-in terminals
n
Customized versions on request
– Special marking
– Special covers (e.g. notches, release features)
Typical applications
Cross carline up to 20A for example: front and rear wiper, air condition,
interior fan.
Contact Data
Contact arrangement
Rated voltage
Limiting continuous current
23°C
85°C
125°C
Limiting making current
1)
Limiting breaking current
1)
Limiting short-time current
overload current, ISO 8820-3
2)
Jump start test
Contact material
Min. recommended contact load
3)
Initial voltage drop
NO contact at 10A, typ./max.
NC contact at 10A, typ./max.
Frequency of operation
Electrical endurance, resistive load at 14VDC
15A
120W lamp (+ on terminal 5)
Mechanical endurance
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5 VDC for 12VDC nominal voltages.
For a load current duration of maximum 3s for a make/break ratio of 1:10.
2) Current and time are compatible with circuit protection by a typical automotive fuse.
Relay will make, carry and break the specified current.
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
1 form A, 1 NO
12VDC
20A
15A
8A
100A
30A
1 form C, 1 CO
12VDC
NO/NC
20/15A
15/10A
8/5A
40A
30A
conducting nominal current at 23°C
silver based
1A at 5VDC
15/300mV
-
6 ops./min (0.1Hz)
>1x10
5
ops.
>1x10
5
ops.
typ. 10
6
ops.
1.35 x 20A, 1800s
2.00 x 20A, 5s
3.50 x 20A, 0.5s
6.00 x 20A, 0.1s
24VDC for 5min,
50/300mV
50/300mV
Coil Data
Rated coil voltage
12VDC
Coil versions, DC coil
Coil
code
*01-402
*01-403
4) Without components in parallel.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Rated
voltage
VDC
12
12
Operate
voltage
VDC
7.2
7.2
Release
voltage
VDC
1.4
1.4
Coil
Rated coil
power
4)
mW
796
567
resistance
4)
±10%
181
254
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Load dump test
ISO 7637-1 (12VDC), test pulse 5
500VAC
rms
500VAC
rms
Vs=+86.5VDC
Micro Relay Low Noise
Automotive Relays
Plug-in Micro ISO Relays
Max. DC load breaking capacity
086LLC07
Load limit curve 1: arc extinguishes uring transit time
Load limit curve 2: safe shutdown, no stationary arc
Coil operating range
Does not take into account
the temperature rise due to
the contact current
E = pre-energization
TE074_OVR1
Does not take into account the temperature rise due to the contact current
E = pre-energization.
F145_fcw1_bw