208
PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
Type BB Same Side Termination - features quick connect terminals with
line and load terminations on the same side of transformer.
Type AE Laydown Termination - features quick connect terminals with line
and load terminations on the top of transformer.
Type AB Opposite Side Termination - features quick connect terminals
with line and load terminations on opposite sides of transformer.
Multiple voltage combinations are available. Consult factory for availability.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications
Terminals:
Standard male quick connects are .250” x .032” (6.35 x .81
mm). Other available quick connects include .187” x .032”
(4.75 x .81 mm) and .187” x .020” (4.75 x .51 mm).
Frequency:
50/60 Hz.
Insulation Class:
UL Class B (130°C).
Weight:
40VA – 22.4 oz. (636 g); 50VA – 35.2 oz. (999 g).
4000 series
Class II UL 1585 Transformer
40VA - 50VA Inherently Energy Limited
No Secondary Fusing Required
Quick Connect Terminals
File E87824
Outline Dimensions
Primary V
Secondary V
40VA
120
24
4000-01E07AE999
120
24
4000-01E07BB999
208/240
24
4000-09E07AE999
Primary V
Secondary V
40VA
50VA
120
24
4000-01E07BB*
4000-01V18BB*
4000-01V18AB*
4000-01AW18BB*
240
24
4000-02E07BB*
4000-02V18BB*
4000-02V18AB*
4000-02AW18BB*
277
24
4000-03E07BB*
4000-03V18BB*
4000-03V18AB*
4000-03AW18BB*
480
24
4000-04E07BB*
4000-04V18BB*
4000-04V18AB*
4000-04AW18BB*
208/240
24
4000-09E07BB*
4000-09V18BB*
4000-09V18AB*
4000-09AW18BB*
380/415
24
4000-51E07BB*
4000-51V18BB*
4000-51V18AB*
4000-51AW18BB*
575
24
4000-78E07BB*
4000-78V18BB*
–
4000-78AW18BB*
Standard “999” Models Available
Partial Listing of Custom Models
* A three digit customer ID suffix will be assigned by the factory.
To specify Type AE Laydown Termination, replace BB in above part numbers with AE.
For more details about standard models see Part
Numbering System table at beginning of
transformer section in this catalog .
.187 DIA
(4.75)
[1] 2.25 (57.15)
[2] 3.125 (79.38)
“A” DIM.
.031
(.787)
.22
(5.59)
.750
(19.05)
“B” DIM.
“A” DIM.
.187 DIA
(4.75)
[1] 2.812 (71.42)
[2] 3.125 (79.38)
40 VA / V18
40 VA / E07
50 VA / AW18
“A” Dimension [inches (mm)]
2.25 (57.15)
2.125 (53.98)
2.56 (65.02)
“B” Dimension [inches (mm)]
1.25 (31.75)
0.875 (22.22)
1.25 (31.75)
Type BB
Same Side
Termination
Type AE
Laydown
Termination
“A” and “B” Dimensions
[1] 2.25 (57.15)
[2] 2.625 (66.68)
[1] 1.50 (38.1)
[2] 1.81 (45.97)
[1] 1.40 (35.56)
[2] 1.494 (37.95)
[1] Applies to V18 models.
[2] Applies to E07 & AW18 models.
“B” DIM.
“A” DIM.
Type AB
Opposite Side
Termination
[1] 1.88 (47.75)
[2] 2.188 (55.58)
[1] 1.88 (47.75)
[2] 2.188 (55.58)
“B” DIM.
[1] 1.40 (35.56)
[2] 1.494 (37.95)
1.0
(2.54)
R .375
(9.53)
[1] 2.25 (57.15)
[2] 2.625 (66.68)
[1] 1.50 (38.1)
[2] 1.81 (45.97)
.048
(1.22)
1.40 (35.56)
[1] 2.25 (57.15)
[2] 2.625 (66.68)
.187 DIA
(4.75)
.031
(.787)
.22
(5.59)
.750
(19.05)
1.55 (39.4)
[1] 2.812 (71.42)
[2] 3.125 (79.38)
R .375
(9.53)
1.88
(47.75)