![](http://datasheet.mmic.net.cn/230000/9513_datasheet_15573014/9513_6.png)
CONDUCTED DISTURBANCE IMMUNITY
BURST (acc. to EN 61000 - 4 - 4) livel 4 (4 kV)
SURGE (acc. to EN 61000 - 4 - 5) livel 4 (4 kV)
40 Series
Miniature P.C.B. Relays 5-10-16 A
AC
DC
Sensitive DC
0.5 W
0.25 W
see diagram R 40/2
≤
0.4 U
N
≥
0.1 U
N
150 A
F (+155°C)
68°C/W
RATED POW ER
MINIMUM POW ER
OPERATING RANGE
HOLDING VOLTAGE
MUST DROP-OUT VOLTAGE
NOMINAL MAGNETOMOTIVE FORCE
THERMAL INSULATION CLASS OF W IRE
THERMAL RESISTANCE
1.2 VA
0.6 VA
0.65 W
0.35 W
(0.8 to 1.1) U
N
≤
0.8 U
N
≥
0.2 U
N
200 A
F (+155°C)
68°C/W
see diagram R 40/1
≤
0.4 U
N
≥
0.1 U
N
180 A
F (+155°C)
68°C/W
VERSIONS:
AC - alternating current 50/60 Hz
DC - direct current
S sensitive - DC voltage with low absorption
14
CONTACT SPECIFICATIONS
Nominal
voltage
U
N
V
Resistance
Nominal coil
absorption
I
U
min
*
V
U
max
V
R
mA
5
3.7
8.8
50
100
6
4.4
10.5
75
80
7
5.1
12.2
100
70
9
6.6
15.8
160
56
12
8.8
21
300
40
14
10.2
24.5
400
35
18
13.2
31.5
650
27.7
21
15.4
36.9
900
23.3
24
17.5
42
1,200
20
28
20.5
49
1,600
17.5
36
26.3
63
2,600
13.8
48
35
84
4,800
10
60
43.8
105
7,200
8.3
90
65.7
157
16,200
5.5
110
80.3
192
23,500
4.7
Nominal
voltage
U
N
V
Resistance
Nominal coil
absorption
U
N
50 Hz
I
mA
U
min
V
U
max
V
R
6
4.8
6.6
21
168
12
9.6
13.2
80
90
24
19.2
26.4
320
45
48
38.4
52.8
1,350
21
60
48
66
2,100
16.8
110
88
121
6,900
9.4
120
96
132
9,000
8.4
230
184
253
28,000
4.5
240
192
264
31,500
4.1
Nominal
voltage
U
N
V
Resistance
Nominal coil
absorption
I
U
min
V
U
max
V
R
mA
5
3.65
7.5
38
130
6
4.4
9
55
109
7
5.1
10.5
75
93
9
6.6
13.5
125
72
12
8.8
18
220
55
14
10.2
21
300
47
18
13.1
27
500
36
21
15.3
31.5
700
30
24
17.5
36
900
27
28
20.5
42
1,200
23
36
26.3
54
2,000
18
48
35
72
3,500
14
60
43.8
90
5,500
11
90
65.7
135
12,500
7.2
110
80.3
165
18,000
6.1
DC VERSION DATA (0.5 W sensitive)
R values relate to +20°C. Tolerance of R and
I
values: ± 10%.
DC VERSION DATA (0.65 W standard)
R values relate to +20°C. Tolerance of R and
I
values: ± 10%.
Operating range
Operating range
*Umin= 0.8 U
N
for 40.61
AC VERSION DATA
R values relate to +20°C. Tolerance of R and
I
values: ± 10%.
Operating range