1
POWER ENTRY MODULES WITH LINE FILTER
5
51
14
45
5
5145
Inlet filter, front side mounting, circuit breaker TA45 2-pole
Standard- or Medical-Filter
C14
70° C
D
De
es
sc
crriip
pttiio
on
n
- Panel Mount:
Screw-on from front side
- 3 Functions:
Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter
6145- We recommend for new applications type
DF12A
Ap
pp
prro
ov
va
alls
s
- VDE License Number: 117118
- UL License Number: E72928
C
Ch
ha
arra
ac
ctte
erriis
sttiic
cs
s
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
W
We
eb
blliin
nk
ks
s
T
Te
ec
ch
hn
niic
ca
all D
Da
atta
a
Ratings IEC
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
Leakage Current
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 A (250 V / 60 Hz)
Dielectric Strength
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Temp.
-10 °C to 55 °C
Climatic Category
10/055/21acc. to, IEC 60068-1
Degree of Protection
from front side IP 40 acc. to IEC 60529
Protection Class
Suitable for appliances with protection
class I acc. to IEC 61140
Terminal
Quick connect terminals 6.3 x 0.8 mm
Panel Thickness s
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Material: Housing
Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold con-
dition) pin-temperature 70 °C, 10 A, Pro-
tection class I
Circuit breaker
Acc. IEC/EN 60934, UL 1077, CSA 22.2
no. 235
2-pole rocker switch, illuminated or non-il-
luminated. Optional with undervoltage- or
remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In
≥
3A/240VAC : 300A
Line Switch
acc. to IEC 61058-1
Line Filter
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
MTBF
> 100'000 h acc. to MIL-HB-217 F