![](http://datasheet.mmic.net.cn/110000/54HC4046RPD_datasheet_3270178/54HC4046RPD_2.png)
SEi - Radiation Hardened 54HC4046RP
Phase-Locked Loop
4031 Sorrento Valley Blvd.
San Diego, CA 92121
(619) 452-4167 Fax (619) 452-5499
Email: sales@spaceelectronics.com
http://www.spaceelectronics.com
2
--9.9--
54HC4046RP ABSOLUTE MAXIMUM RATINGS 1/ 2/
PARAMETER
SYMBOL
MIN
MAX
UNIT
Supply Voltage
VCC
-0.5
+7.0
V
DC Input Voltage
VIN
-0.5
VCC+0.5
V
DC Output Voltage
VOUT
-0.5
VCC+0.5
V
Clamp Diode Current
IIK, IOK
±20
mA
DC Output Current, per pin
IOUT
+25
mA
DC VCC or GND Current, per
pin
ICC
±50
mA
Storage Temperature Range
TSTG
-65
+150
oC
Power Dissipation
PD
500
mW
Note:
1/ Maximum Ratings are those values beyond which damage to the
device may occur.
2/ All voltages are referenced to ground, unless otherwise specified.
54HC4046RP OPERATING CONDITIONS
PARAMETER
SYMBOL
MIN
MAX
UNIT
Supply Voltage
VCC
+2.0
+6.0
V
DC Input or Output
Voltage
VIN, VOUT
0
VCC
V
Operating
Temperature Range
TA
-55
+125
oC
Input Rise or Fall
Times
VCC = 2.0V
VCC = 4.5V
VCC = 6.0V
tr, tf
0
1000
500
400
ns
54HC404SRP DC ELECTRICAL CHARACTERISTICS
1
PARAMETER
SYMBOL
TYP
MAX
UNIT
Minimum High Level Input Voltage
VCC = 2.0V
VCC = 4.5V
VCC = 6.0V
VIH
1.5
3.15
4.2
V
Maximum Low Level Input Voltage
VCC = 2.0V
VCC = 4.5V
VCC = 6.0V
VIL
0.5
1.35
1.8
V
Minimum High Level Output Voltage
VIN = VIH or VIL
|IOUT|
≤20uA
VCC = 2.0V
VCC = 4.5V
VCC = 6.0V
VIN=VIH or VIL
|IOUT|
≤4.0mA @VCC = 4.5V
|IOUT|
≤5.2mA @VCC = 6.0V
VOH
2.0
4.5
6.0
4.2
5.7
1.9
4.4
5.9
3.7
5.2
V
Maximum Low Level Output Voltage
VIN = VIH or VIL
|IOUT|
≤20uA
VCC = 3.0V
VCC = 4.5V
VCC = 6.0V
VIN = VIH or VIL
|IOUT|
≤4.0mA @VCC = 4.5V
|IOUT|
≤5.2mA @VCC = 6.0V
VOL
0.1
0.4
V
Input Current
VIN=VCC or GND @VCC=6.0V
Pin 3, 5, 9
Pin 14
IIN
+1.0
100
uA
Maximum Tri-State Output Leakage Current
(pin 13)
VOUT = VCC or GND @ VCC = 6.0V
IOZ
+10
uA
Maximum Quiescent Supply Current
VIN = VCC or GND , IOUT = 0uA, @VCC = 6.0V
VIN = VCC or GND, Pin 14 Open, @VCC = 6.0V
ICC
30
600
160
3000
uA
Note:
1. For a power supply of 5V
±10% the worst case output voltages (VOH and VOL) occur at 4.5V. Thus the 4.5V values should be used when designing
with this supply. Worst case VIH and VIL occur at VCC = 5.5V and 4.5V respectively. The worst case leakage current (IIN, ICC, and IOZ) occur for CMOS at