5V AC Parameters
The following conditions apply, unless otherwise specified.
V+ = 5V, V - = 0V, V
CM = 2.5V, VO = 2.5V, and RL > 1 MΩ.
Symbol
Parameter
Conditions
Notes
Typ
Min
Max
Units
Sub-
groups
GBW
Gain-Bandwidth Product
3
1
5
MHz
4
SR
Slew Rate
4
V/
μs
θ
m
Phase Margin
60
Deg
G
m
Gain Margin
15
dB
e
n
Input-Referred Voltage Noise
35
nV/
e
nP-P
Input-Referred Voltage Noise
R
S = 100, DC to 10 Hz
850
nV
PP
t
rec
Input Overload Recovery Time
50
ms
5V DC Parameters – 50 krad(Si) Post Radiation Limits @ +25°C
The following conditions apply, unless otherwise specified.
V+ = 5V, V - = 0V, V
CM = 2.5V, VO = 2.5V, and RL > 1 MΩ.
Symbol
Parameter
Conditions
Notes
Typ
Min
Max
Units
Sub-
groups
I
S
Supply Current per Channel
1.75
mA
1
5V Operating Life Test Delta Parameters T
A = +25°C
This is worst case drift, deltas are performed at room temperature post operation life. All other parameters, no deltas required.
Symbol
Parameter
Conditions
Limit
Units
V
IO
Input offset voltage
5.0 V
±2
μV
Note 1:
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2:
The maximum power dissipation must be derated at elevated temperatures and is dictated by T
Jmax (maximum junction temperature), θJA (package
junction to ambient thermal resistance), and T
A (ambient temperature). The maximum allowable power dissipation at any temperature is PDmax = (TJmax - TA)/
θ
JA or the number given in the Absolute Maximum Ratings, whichever is lower.
Note 3:
Human body model, 1.5 k
Ω in series with 100 pF.
Note 4:
Typical values represent the most likely parametric norm.
Note 5:
Pre and post irradiation limits are identical to those listed under DC Parameters, except those listed in the Post Radiation Limit tables.
www.national.com
6
LMP2012QML