1
n
60% volume reduced Power K at increased performance
n
PCB area requirements minimized by 50% to only 293mm
2
n
Size optimized to lwh (mm) 18.3x16x15.9
n
Limiting continuous current 40A
n
Maximum switch on current 200A
n
Increased ambient temperature 105°C
n
Design allows highest reliability
n
High shock and vibration resistance
n
Wave (THT) and reflow (THR/pin-in-paste) solderable versions
n
For latching (bistable) version refer to Power Relay PK2 Latching
Typical applications
ABS control, blower fans, cooling fan, engine control, fuel pump, glow plug,
hazard warning signal, switched power supply.
Contact Data
Contact arrangement
Rated voltage
Rated current
Limiting continuous current
23°C
85°C
105°C
Limiting making current
Limiting breaking current
Contact material
Min. recommended contact load
Initial voltage drop at 10A, typ./max.
Frequency of operation at nominal load
Operate/release time max.
Electrical endurance
at cyclic temperature -40/+23/+85°C
and 13.5VDC and 120ms (on), 4.88s (off)
Inductive load: L=0.5mH, 60A (on)/35A (off) >1x10
5
ops.
5)
resistive load: 40A (on)/40A (off)
capacitive load 200A (on)/20A (off)
1 form A, 1 NO
12VDC
40A
1)
40A
1)
33A
1)
22A
1)
200A
2)
40A
2)
AgSn0
1A at 5VDC
3)
30/300mV
6 ops./min (0.1Hz)
typ. 3/1.5ms
4)
>1x10
5
ops.
5)
>1x10
5
ops.
5)
Contact Data
(continued)
Mechanical endurance
1) Measured on 70x70x1.5mm epoxy PCB FR4 with 52cm
2
(double layer 140μm) copper
area.
2) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC load voltages.
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay
coil increases the release time and reduces the lifetime caused by increased erosion
and/or higher risk of contact tack welding (monostable version only).
5) Be aware of using right polarity, see Terminal Assignment. Wrong polarity will reduce
endurance.
>2x10
6
ops.
Coil Data
Rated coil voltage
12VDC
Coil versions, DC coil
Coil
code
001/005
009
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Rated
voltage
VDC
12
10
Operate
voltage
VDC
6.9
5.6
Release
voltage
VDC
1.5
1.3
Coil
Rated coil
power
mW
818
833
resistance
±10%
176
120
Power Relay PK2 (THT – THR)
Automotive Relays
PCB Single Relays
201C_LLC3
Coil operating range
201C_OVR1
Load limit curve: safe shutdown, no stationary arc/make contact.
Load limit curves measured with low inductive resistors verified for 1000 switching events.
Does not take into account the temperature rise due to the contact current
E = pre-energization.
F201Rfcw2b
Max. DC load breaking capacity