69
60 Series
General Purpose Relays 10 A
AC
DC
RATED POW ER
OPERATING RANGE
HOLDING VOLTAGE
MUST DROP-OUT VOLTAGE
NOMINAL MAGNETOMOTIVE FORCE
THERMAL INSULATION CLASS OF W IRE
THERMAL RESISTANCE
2.2 VA
1.3 W
(0.8 ... 1.1) U
N
≤
0.8 U
N
≥
0.2 U
N
180 A
F (+155°C)
43°C/W
(0.8 ... 1.1) U
N
≤
0.5 U
N
≥
0.1 U
N
250 A
F (+155°C)
43°C/W
CONDUCTED DISTURBANCE IMMUNITY
BURST (acc. to EN 61000 - 4 - 4) level 4 (4 kV)
SURGE (acc. to EN 61000 - 4 - 5) level 4 (4 kV)
VERSIONS:
AC - alternating current 50/60 Hz
DC - direct current
AM - current sensing
DI - DC coil with a diode in parallel
COILSPECIFICATIONS
Rated
voltage
U
N
V
Resistance
Nominal coil
absorption
I
U
min
V
4.8
9.6
19.2
38.4
48
88
U
max
R
V
6.6
13.2
26.4
52.8
66
121
mA
6
28
214
109
53.9
27.1
21.7
11.7
12
24
48
60
110
445
1,770
2,760
9,420
110
Rated
voltage
U
N
V
6
12
24
48
60
110
120
230
240
Resistance
Nominal
coil
absorption
U
N
50 Hz
I
mA
367
183
91.7
45.8
36.7
20
18.6
9.6
9.2
U
min
V
4.8
9.6
19.2
38.4
48
88
96
184
192
U
max
V
6.6
13.2
26.4
52.8
66
121
132
253
264
R
4.6
19
80
320
500
1,800
1,940
7,250
8,500
Operating range
Coil code
4501
4451
4401
4361
4321
4281
4251
4231
4201
4181
4161
4141
4121
4101
4091
4081
4071
4061
4051
4041
4031
4021
4011
I
min
(A)
4.25
3.8
3.4
3.0
2.7
2.4
2.1
1.9
1.7
1.5
1.4
1.2
1.0
0.85
0.8
0.7
0.6
0.5
0.42
0.34
0.25
0.17
0.085
I
N
(A)
5.0
4.5
4.0
3.6
3.2
2.8
2.5
2.3
2.0
1.8
1.6
1.4
1.2
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
I
max
(A)
6.0
5.4
4.8
4.3
3.8
3.4
3.0
2.8
2.4
2.2
1.9
1.7
1.4
1.2
1.1
1.0
0.9
0.7
0.6
0.5
0.4
0.25
0.15
R (
)
0.01
0.02
0.02
0.02
0.03
0.04
0.05
0.06
0.08
0.10
0.12
0.16
0.22
0.32
0.40
0.50
0.65
0.89
1.28
2.00
3.57
8.0
32.1
Operating range
AC VERSION DATA
R values relate to +20°C. Tolerance of R and
I
values: ± 10%.
DC VERSION DATA
R values relate to +20°C. Tolerance of R and
I
values: ± 10%.
CURRENT SENSING AC
R values relate to +20°C. Tolerance of R and
I
values: ± 10%.
Coil code
4502
4452
4402
4362
4322
4282
4252
4232
4202
4182
4162
4142
4122
4102
4092
4082
4072
4062
4052
4042
4032
4022
4012
I
min
(A)
4.25
3.8
3.4
3.0
2.7
2.4
2.1
1.9
1.7
1.5
1.4
1.2
1.0
0.85
0.8
0.7
0.6
0.5
0.42
0.34
0.25
0.17
0.085
I
N
(A)
5.0
4.5
4.0
3.6
3.2
2.8
2.5
2.3
2.0
1.8
1.6
1.4
1.2
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
I
max
(A)
6.0
5.4
4.8
4.3
3.8
3.4
3.0
2.8
2.4
2.2
1.9
1.7
1.4
1.2
1.1
1.0
0.9
0.7
0.6
0.5
0.4
0.25
0.15
R (
)
0.020
0.030
0.038
0.047
0.059
0.077
0.10
0.13
0.15
0.19
0.24
0.31
0.42
0.61
0.75
0.95
1.24
1.70
2.40
3.80
6.70
15.2
61
CURRENT SENSING DC
R values relate to +20°C. Tolerance of R and
I