The arm’s custom neck piece allows for easy mounting of a
standard Jr. Ionizer via the stand assembly. The ionizer should
be mounted to the arm by tightening the bolt onto the neck
piece as shown in Figure 5.
TB-2095 Page 2 of 5
Installation
Remove the ionizer from the carton and inspect for damage.
Included with the unit should be:
1 Air Filter
1 Stand Assembly with Hardware
1 Power Cord
Mount the unit in the desired position. Set the front panel
rocker switch to the “off” or mid position.
Install the power cord into an appropriate power source.
Chargebuster Jr. models
VAC 50/60 Hz. The ionizer must be connected to a properly
grounded receptacle for operation.
NOTE: We recommend not using on the same circuit as
motors or equipment drawing heavy current as false alarms
may occur.
Installing Stand Assembly
To install the stand assembly follow the instructions shown in
Figure 3. You can mount the unit on a bench top or remove
the rubber feet and bolt the stand to a wall or under a shelf as
desired. Be sure to use appropriate fasteners. For best results,
mount the unit so that no obstructions exist either on the intake
or the outlet side.
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Website: Desco.com 2012 DESCO INDUSTRIES, INC.
Employee Owned
Ionizer
Housing
Stand
Flat Washer
Knob
Figure 3. Installing stand assembly
Alternative Mounting
Use the
60466 Ionizer Mounting Arm as a mounting alternative
for the Chargebuster Jr. Ionizer. The Ionizer Mounting Arm
allows the Chargebuster Jr. Ionizer to be mounted off the
bench top, saving valuable work bench space. The articulated
movement of the arm assembly allows the user to precisely
focus the ionizer’s output directly onto the desired areas or
across the entire work area.
The Ionizer Mounting Arm includes a C-clamp style mounting
system for ease of installation. Figure 4 shows proper
mounting of the arm on a workbench. The arm also includes an
installed three prong power cord with an IEC termination.
Figure 4. Installing mounting arm on workbench.
Figure 5. Installing Chargebuster Jr. to Ionizer Mounting Arm
The
60460 is sold separately. For detailed information on the
installation and operation of the 60460 Ionizer Mounting Arm,
ask for Technical Bulletin
Operation
For item
60500 set the front panel rocker fan switch to either
“HIGH” or “LOW” fan speed. Higher air flow will result in a
faster neutralization rate. Safety interlock switches are provided
internally on the emitter cassette. This insures that power is
cut off in the event that the cassette is removed or not fully
installed.
Aim the unit so that the maximum airflow is directed at the
items or area to be neutralized.
The bottom rocker switch on the
60501 turns on a heater which
will raise the temperature of the output air to about 10°F above
ambient. The heater is only to offset the chill factor of the
moving air. It is not intended to warm the workstation.
If the ionizer is used in a manner not specified by the
manufacturer, the protection provided by the ionizer may
be impaired.