Schurter, Inc. Phone 707-778-6311 Fax 707-778-6401 E-mail info@schurterinc.com Website http://www.schurterinc.com
122
How To Or der
PF LT . 100. S
Product
Designator
Style
LT = Low Temperature Axial Leaded “Strap” Component
Hold Current, Ihold
100-340 (1.00 Amps - 3.40 Amps)
Slotted Lead Option
(100.s and 180.s only)
Thermal Derating Chart - Ihold (Amps)
Ambien
t Operating Temperature
Model
-40 C
-20C
0C
23C
40C
50C
60C
70C
85C
PFLT.100.S
1.8
1.6
1.4
1.0
0.8
0.7
0.6
0.4
0.2
PFLT.180
3.1
2.6
2.2
1.8
1.3
1.1
0.9
0.6
0.2
PFLT.180.S
3.1
2.6
2.2
1.8
1.3
1.1
0.9
0.6
0.2
PFLT.190
3.3
2.8
2.4
1.9
1.4
1.2
1.1
0.7
0.4
PFLT.260
4.3
3.7
3.1
2.6
1.9
1.6
1.4
1.1
0.6
PFLT.300
5.1
4.4
3.7
3.0
2.3
1.9
1.6
1.2
0.6
PFLT.340
5.5
4.7
4.0
3.4
2.6
2.2
1.9
1.5
0.8
Schurter’s resettable fuses cross to many like products already on the market.
Electrical Characteristics
1 Hour (R1)
Max.Time
Tripped
Ihold
Itrip
Initial
Post- Trip
To Trip
Power
Resistance
at 5*Ih
Dissipation
Model
Amperes
Ohms
Seconds
Watts
V max.
I max.
at 2 3°C
Volts
Amps
Hold
Trip
Min.
Max.
PFLT.100.S
24
100
1.0
2.5
0.070
0.130
0.260
7.0
1.5
PFLT.180
24
100
1.8
3.8
0.040
0.068
0.120
2.9
2.0
PFLT.180.S
24
100
1.8
3.8
0.040
0.068
0.120
2.9
2.0
PFLT.190
24
100
1.9
4.2
0.030
0.057
0.100
3.0
1.9
PFLT.260
24
100
2.6
5.2
0.025
0.042
0.076
5.0
2.3
PFLT.300
24
100
3.0
6.3
0.015
0.031
0.055
4.0
2.0
PFLT.340
24
100
3.4
6.8
0.016
0.027
0.050
5.0
2.7
All models packaged loose. Optional slotted leads (.S) available for 1A and 1.8A ratings.
PF LT Technical Data ,continued