7
Commercial Temperature Range
IDT72V8981 3.3V Time Slot Interchange
Digital Switch 128 x 128
Test Point
Output
Pin
CL
GND
S1
RL
VCC
GND
5702 drw08
S2
S1 is open circuit except when testing
output levels or high impedance states.
S2 is switched to VCC or GND when
testing output levels or high impedance
states.
Figure 4. Output Load
RECOMMENDED OPERATING
CONDITIONS
DC ELECTRICAL CHARACTERISTICS
NOTE:
1. Typical figures are at 25
°C and are for design aid only; not guaranteed and not subject
to production testing.
NOTE:
1. Typical figures are at 25
°C and are for design aid only; not guaranteed and not subject to production testing.
Symbol
Parameter
Min.
Max.
Unit
Vcc
Symbol Voltage
-0.3
5
V
Vi
Voltage on Digital Inputs
GND - 0.3
VCC +0.5
V
VO
Voltage on Digital Outputs
GND - 0.3
VCC +0.3
V
IO
Current at Digital Outputs
20
mA
TS
StorageTemperature
-55
+125
° C
PD
Package Power Dissapation
1
W
Symbol
Parameter
Min.
Typ.(1)
Max.
Unit
VCC
Positive Supply
3.0
3.6
V
VI
InputVoltage
0
5.25
V
TOP
OperatingTemperature
-40
25
+85
°C
Commercial
Symbol
Parameter
Min.
Typ.(1)
Max.
Units
Test Conditions
ICC
Supply Current
3
5
mA
OutputsUnloaded
VIH
Input High Voltage
2.0
V
VIL
Input Low Voltage
0.8
V
IIL
InputLeakage
15
AVI between GND and VCC
CI
InputCapacitance
pF
VOH
Output High Voltage
2.4
VIOH = 10mA
IOH
Output High Current
10
mA
Sourcing. VOH = 2.4V
VOL
Output Low Voltage
0.4
V
IOL = 5mA
IOL
Output Low Current
5
mA
Sinking. VOL = 0.4V
IOZ
High Impedance Leakage
5
AVO between GND and VCC
CO
Output Pin Capacitance
10
pF
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation of
the device at these or any other conditions above those indicated in the operational sections
of this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect reliability.
ABSOLUTE MAXIMUM RATINGS (1)