Philips Semiconductors
Product specification
74LV4316
Quad bilateral switches
1998 Jun 23
5
DC ELECTRICAL CHARACTERISTICS
Over recommended operating conditions. Voltages are referenced to GND (ground = 0 V).
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
-40
°C to +85°C
-40
°C to +125°C
UNIT
MIN
TYP1
MAX
MIN
MAX
VCC = 1.2 V
0.90
HIGH level Input
VCC = 2.0 V
1.40
1.4
VIH
HIGH level Input
voltage
VCC = 2.7 to 3.6 V
2.00
2.0
V
voltage
VCC = 4.5 V
3.15
VCC = 6.0 V
4.20
VCC = 1.2 V
0.30
LOW level Input
VCC = 2.0 V
0.60
VIL
LOW level Input
voltage
VCC = 2.7 to 3.6 V
0.80
V
voltage
VCC = 4.5 V
1.35
VCC = 6.0 V
1.80
±II
Input leakage
current
VCC = 3.6 V; VI = VCC or GND
VCC = 6.0 V; VI = VCC or GND
1.0
2.0
1.0
2.0
A
±IS
Analog switch
OFF-state current
per channel
VCC = 3.6 V; VI = VIH or VIL
VCC = 6.0 V; VI = VIH or VIL
1.0
2.0
1.0
2.0
A
±IS
Analog switch
ON-state current
per channel
VCC = 3.6 V; VI = VIH or VIL
VCC = 6.0 V; VI = VIH or VIL
1.0
2.0
1.0
2.0
A
ICC
Quiescent supply
current
VCC = 3.6V; VI = VCC or GND; IO = 0
VCC = 6.0V; VI = VCC or GND; IO = 0
20
40
80
A
ICC
Additional
quiescent supply
current per input
VCC = 2.7 V to 3.6 V; VI = VCC – 0.6 V
500
850
A
RON
ON-resistance
(peak)
VCC = 1.2 V; VI = VIH or VIL
VCC = 2.0 V; VI = VIH or VIL
VCC = 2.7 V; VI = VIH or VIL
VCC = 3.0 to 3.6 V; VI = VIH or VIL
VCC = 4.5 V; VI = VIH or VIL
VCC = 6.0 V; VI = VIH or VIL
295
120
110
80
70
–
860
300
270
200
180
–
990
360
325
240
215
RON
ON-resistance
(rail)
VCC = 1.2 V; VI = VIH or VIL
VCC = 2.0 V; VI = VIH or VIL
VCC = 2.7 V; VI = VIH or VIL
VCC = 3.0 to 3.6 V; VI = VIH or VIL
VCC = 4.5 V; VI = VIH or VIL
VCC = 6.0 V; VI = VIH or VIL
225
110
85
55
40
35
–
240
150
135
100
90
–
290
180
120
110
RON
ON-resistance
(rail)
VCC = 1.2 V; VI = VIH or VIL
VCC = 2.0 V; VI = VIH or VIL
VCC = 2.7 V; VI = VIH or VIL
VCC = 3.0 to 3.6 V; VI = VIH or VIL
VCC = 4.5 V; VI = VIH or VIL
VCC = 6.0 V; VI = VIH or VIL
250
120
75
60
45
40
–
270
170
155
115
105
–
325
205
180
135
120
RON
Maximum variation
of ON-resistance
between any two
channels
VCC = 1.2 V; VI = VIH or VIL
VCC = 2.0 V; VI = VIH or VIL
VCC = 2.7 V; VI = VIH or VIL
VCC = 3.0 to 3.6 V; VI = VIH or VIL
VCC = 4.5 V; VI = VIH or VIL
VCC = 6.0 V; VI = VIH or VIL
–
5
4
3
2
NOTE:
1. All typical values are measured at Tamb = 25°C.
2. At supply voltage approaching 1.2V, the analog switch ON-resistance becomes extremely non-linear. Therefore it is recommended that
these devices be used to transmit digital signals only, when using these supply voltages.