TJA1055_4
NXP B.V. 2009. All rights reserved.
Product data sheet
Rev. 04 — 17 February 2009
15 of 26
NXP Semiconductors
TJA1055
Enhanced fault-tolerant CAN transceiver
[1]
All parameters are guaranteed over the virtual junction temperature range by design, but only 100 % tested at Tamb = 125 °C for dies on
wafer level, and above this for cased products 100 % tested at Tamb =25 °C, unless otherwise specied.
[2]
To guarantee a successful mode transition under all conditions, the maximum specied time must be applied.
tPD(H)
propagation delay TXD (HIGH) to
RXD (HIGH)
no failures; RCAN_L =RCAN_H = 125 ;
-
1.5
s
all failures except CAN_L shorted to CAN_H;
RCAN_L =RCAN_H = 125 ; CCAN_L =
-
1.9
s
failure 7, CAN_L shorted to CAN_H;
RCAN_L = 1 M; RCAN_H = 125 ; CCAN_L =
-
1.9
s
td(sleep)
delay time to sleep
50
s
tdis(TxD)
disable time of TxD permanent
dominant timer
normal operating mode; VTXD = 0 V
0.75 -
4
ms
tdom(CANH) dominant time on pin CANH
low power modes; VBAT =14V
38
s
tdom(CANL)
dominant time on pin CANL
low power modes; VBAT =14V
38
s
tWAKE
local wake-up time on pin WAKE
low power modes; VBAT = 14 V; for wake-up
after receiving a falling or rising edge
38
s
tdet
failure detection time
normal operating mode
failures 3 and 3a
1.6
-
8.0
ms
failures 4, 6 and 7
0.3
-
1.6
ms
low power modes; VBAT =14V
failures 3 and 3a
1.6
-
8.0
ms
failures 4 and 7
0.1
-
1.6
ms
trec
failure recovery time
normal operating mode
failures 3 and 3a
0.3
-
1.6
ms
failures 4 and 7
7
-
38
s
failure 6
125
-
750
s
low power modes; VBAT =14V
failures 3, 3a, 4 and 7
0.3
-
1.6
ms
ndet
pulse-count failure detection
difference between CANH and CANL;
normal operating mode and failures 1, 2, 5
and 6a; pin ERR becomes LOW
-4
-
nrec
number of consecutive pulses for
failure recovery
on CANH and CANL simultaneously;
failures 1, 2, 5 and 6a
-4
-
Table 9.
Dynamic characteristics …continued
VCC = 4.75 V to 5.25 V; VBAT = 5.0 V to 40 V; VSTB =VCC; Tvj = 40 °C to +150 °C; all voltages are dened with respect to
ground; unless otherwise specied.[1]
Symbol
Parameter
Conditions
Min
Typ
Max Unit