![](http://datasheet.mmic.net.cn/230000/93M5AKF_datasheet_15572637/93M5AKF_4.png)
MIM-93M5XKF SERIES
Reliability
Test item
Test condition
Standard
Note 2.
Note 2.
Note 2.
Note 2.
Note 3.
High temparature
High temp. & high humi.
Low temparature
Heat cycle
Dropping
Ta=+60
Ta=+40
Ta= -10
-20
Test devices shall be dropped 3 times naturally
onto hard wooden board from a 75cm height position.
Vcc=5.0 V t=240H
90%RH Vcc=5.0V t=240H
Vcc=5.0V t=240H
(0.5H) ~ +75
(0.5H) 20cycle
NOTE 2. (electro-optical charactistics) shall be satisfied after leaving 2 hours in the normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
and destructions of appearance .(excepting deforms of terminals)
Inspection standard
1.Among electrical characteristics , total number shall be inspected on items blow.
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
CAUTION ( When use and storage of this device )
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
, the soldering iron is connected to ground before using .
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
Guarantee period and scope
1.Guarantee period
One year after delivery to desired place .
2.Guarantee scope
device .However no responsibilities be taken for the inconveniences caused by
the malfunction of our devices .
Others
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
covering the said problem .
01/10/2002