![](http://datasheet.mmic.net.cn/240000/A101120006_datasheet_15640300/A101120006_2.png)
2
Specifications are subject to change without notice (25.10.99)
A 108, A 101, A 208, A 201
A 108, A 101
A 208, A 201
Output
Basic electrical insulation
Contact ratings
(Ag-CdO)
Resistive loads
SPDT relay
250 VAC (rms) (contact/electronics)
μ (micro gap)
10 A/250 VAC (2500 VA)
1 A/250 VDC (250 W)
10 A/25 VDC (250 W)
AC 15 2.5 A/230 VAC
DC 13 5 A/24 VDC
≥
30 x 10
6
operations
AC 1
≥
2.5 x 10
5
operations (at max. load)
≤
7200 operations/h
DPDT relay
250 VAC (rms) (contacts/elec., contact/contact)
μ (micro gap)
8 A/250 VAC (2000 VA)
0.4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
5 A/24 VDC
≥
30 x 10
6
operations
≥
2.5 x 10
5
operations (at max. load)
≤
7200 operations/h
AC 1
DC 1
or
Small inductive loads
Mechanical life
Electrical life
Operating frequency
Insulation voltages
Rated insulation voltage
Rated transient protection volt.
4 kV (1.2/50 μs) (contact/electronics) (IEC 60664)
≥
2.0 kVAC (rms) (contact/electronics)
≥
2.0 kVAC (rms) (contact/electronics)
4 kV (1.2/50 μs) (contact/electronics) (IEC 60664)
Power supply
A 101, A 201
Power-on delay
Power-off delay
Indication for
Output ON
Environment
Polution degree
Operating temperature
Storage temperature
Weight
Approvals
≤
200 ms
≥
250 ms
LED, red
IP 20 B
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
85 g
UL, CSA
Power supply AC types
Rated operational voltage
through pins 2 & 10
or pins 2 & 7
installation cat. III (IEC 60664)
220
220 VAC + 15/- 20%,
45 to 65 Hz
120 VAC + 15/- 20%,
45 to 65 Hz
24 VAC + 15/- 20%,
45 to 65 Hz
≥
10 ms
None
120
024
Drop out tolerance
Rated insulation voltage
Rated transient protection volt. 4 kV (1.2/50 μs) @ 220 VAC
2.5 kV (1.2/50 μs) @ 120 VAC
800 V (1.2/50 μs) @ 24 VAC
(line/neutral)
Installation cat. III (IEC 60664)
24 VDC + 15/- 20% (pin 2 pos.)
None
Power supply DC type
Rated operational voltage 024
Rated insulation voltage
Rated transient protection volt. 800 V (1.2/50 μs)
Consumption
AC supply
DC supply
60 mA @ 50 Hz/70 mA @ 60 Hz
1 W
Mode of Operation
The delay period begins when
power supply is applied.
At the end of the set delay,
the relay will operate and will
not release until power sup-
ply is interrupted.
A recovery period of 250 ms
should be allowed before re-
applying power supply.
If power supply is interrupted
for more than 250 ms before
the relay operates, the time
circuit is reset to zero and the
time relay is ready for a new
time period.
Wiring Diagrams
Output Specifications
Supply Specifications
General Specifications
Power supply
A 108, A 208