Aeroflex Circuit Technology
SCD8600 REV B 2/8/02 Plainview NY (516) 694-6700
3
Adjustment Pin Current
Change con’t
I
ADJ
3V < V
DIFF
< 40V, T
A
= + 25°C
3.3V < V
DIFF
< 40V
-
-
±5
±5
μA
μA
Minimum Load Current
I
LMIN
V
DIF
= 3.0V, V
OUT
= 1.4 (forced), T
A
= + 25°C
V
DIF
= 3.3V, V
OUT
= 1.4 (forced)
V
DIF
= 40V, V
OUT
= 1.4 (forced)
-
-
-
5
5
5
mA
mA
mA
Current Limit 2/
I
CL
V
DIF
= 15V
V
DIF
= 40V, T
A
= + 25°C
1.5
0.18
3.5
1.5
A
A
Notes:
1/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating
effects are covered under the specification for thermal regulation. With exception of cases U and 2, all output measurements are referenced
to the case. Measurements taken at the output lead must be adjusted for lead resistance.
2/ If not tested, shall be guaranteed to the specified limits.
Negative Regulator
Electrical Performance Characteristics
(T
A
= -55°C to +125°C, I
L
= 8mA, Unless otherwise specified)
Parameter
Sym
Conditions
Min
Max
Units
Reference Voltage
V
REF
V
DIF
= 3.0V, T
A
= + 25°C
V
DIF
= 3.0V
V
DIF
= 40V, T
A
= + 25°C
V
DIF
= 40V
-1.275
-1.3
-1.275
-1.3
-1.225
-1.2
-1.225
-1.2
V
V
V
V
Line Regulation
R
LINE
3.0V < V
DIF
< 40V, V
OUT
= V
REF
, T
A
= + 25°C
3.0V < V
DIF
< 40V, V
OUT
= V
REF
-
-
±9
±23
mV
mV
Load Regulation 1/
R
LOAD
V
DIF
= 12V, 8mA < I
L
< 1.5A, T
A
= + 25°C
V
DIF
= 5V, 8mA < I
L
< 1.5A
V
DIF
= 40V, 8mA < I
L
< 200mA, T
A
= + 25°C
V
DIF
= 40V, 8mA < I
L
< 100mA
-
-
-
-
±25
±25
±25
±25
mV
mV
mV
mV
Thermal Regulation
V
RTH
V
IN
= -14.6V, I
L
= 1.5A, t = 10ms, P
D
= 20W,
T
A
= + 25°C
-
±5
mV
Ripple Rejection
R
N
f = 120Hz, C
ADJ
= 10μF, V
OUT
= V
REF
2/
66
-
dB
Adjustment Pin Current
I
ADJ
V
DIF
= 3.0V
V
DIF
= 40V
-
-
100
100
μA
μA
Adjustment Pin Current
Change
I
ADJ
(Line)
I
ADJ
(Load)
3.0V < V
DIF
< 40V
V
DIF
= 5.0V, 8mA < I
L
< 1.5A
-
-
±5
±5
μA
μA
Minimum Load Current
I
LMIN
V
DIF
= 3.0V, V
OUT
= -1.4 (forced)
V
DIF
= 10V, V
OUT
= 1.4 (forced)
V
DIF
= 40V, V
OUT
= 1.4 (forced)
-
-
-
3
3
5
mA
mA
mA
Current Limit 2/
I
CL
V
DIF
= 5V
V
DIF
= 40V, T
A
= + 25°C
1.5
0.24
3.5
1.2
A
A
Notes:
1/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating
effects are covered under the specification for thermal regulation. With exception of cases U and 2, all output measurements are referenced
to the case. Measurements taken at the output lead must be adjusted for lead resistance.
2/ If not tested, shall be guaranteed to the specified limits.
Positive Regulator
Electrical Performance Characteristics (con’t)
(T
A
= -55°C to +125°C, I
L
= 8mA, Unless otherwise specified)
Parameter
Sym
Conditions
Min
Max
Units