參數(shù)資料
型號(hào): ASC7531BM10
廠商: Electronic Theatre Controls, Inc.
元件分類(lèi): 溫度/濕度傳感器
英文描述: LOW-VOLTAGE 1-WIRE DIGITAL TEMPERATURE SENSOR AND VOLTAGE MONITOR
中文描述: 低電壓1 - Wire數(shù)字溫度傳感器和電壓監(jiān)測(cè)
文件頁(yè)數(shù): 11/18頁(yè)
文件大?。?/td> 196K
代理商: ASC7531BM10
- 11 -
Andigilog, Inc. 2006
www.andigilog.com
December
2006 - 70A05012
aSC7531A / aSC7531B
Reserved or Unsupported Commands
Attempts to access the sensor using a reserved or unsupported command will not result in the device or bus failure. The sensor will
return a modified FCS when any of the following commands are received. To modify the FCS the sensor will invert all of the bits in
the correct FCS (1’s complement). A modified FCS is also called an Abort FCS.
The sensor will return an Abort FCS (modified FCS) for a reserved and unsupported command code (commands codes between
0xE4 to 0xF5 and 0xF8 to 0xFF).
The sensor will return an Abort FCS (modified FCS) for reserved commands (command codes 0x02 to 0x0F and 0x15 to 0xDF).
The sensor will return an Abort FCS (modified FCS) for unused vendor specific test and manufacturing command codes (command
codes 0xE8 to 0xEF). If any of these types of commands exist, they will be disabled during normal operation.
Malformed Commands
A malformed command is one which is valid but has an incorrect write or read length for the given command.
If a get temperature or get voltage command with a write length not equal to 1 is sent, then the aSC7531 will send an Abort FCS
and wait for a new command. An Abort FCS will be formed by creating a 1’s complement of the good FCS.
If a get temperature or get voltage command and the read length is not equal to 2, 4, or 10 then the aSC7531 will send an Abort
FCS and wait for a stop on the SST bus. See the Command Summary section for the expected Write and Read lengths of the legal
commands.
There will be no checking for malformed WriteReg() and ReadReg() commands (Vendor Specific Extensions).
Command Summary
Hex Cmd
Command Name
Received Bytes
Wr Len
Rd Len
Bytes Sent by Client
-
0x00
0x01
0x00
0x02-0x0F
0x10
0x11
0x12
0x13
0x14
0x10
0x15-0xDF
0xE0
0xE1
0xE2
0xE3
0xE4-0xF5
0xF6
0xF6
0xF7
0xF7
0xF8-0xFF
Ping()
3(target,wr,rd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
4(target,wr,rd,cmd)
0
1
1
1
1
1
1
1
1
1
3+
2
1
1
1
1
1
1
0
2
2
4
2
2
2
2
2
10
0
1+
0
0
0
0
8
16
FCS
FCS/2/FCS
FCS/2/FCS
FCS/4/FCS
Abort FCS
FCS/2/FCS
FCS/2/FCS
FCS/2/FCS
FCS/2/FCS
FCS/2/FCS
FCS/10/FCS
Abort FCS
FCS
FCS/1+/FCS
FCS
FCS
Abort FCS
FCS
None if default address (0x00)
FCS/8/FCS
FCS/16/FCS
Abort FCS
GetIntTemp()
GetExtTemp()
GetAllTemps()
Unsupported
GetVolt12V()
GetVolt5V()
GetVolt3p3V()
GetVolt2p5V()
GetVoltVccp()
GetAllVoltages()
Unsupported
WriteReg()
ReadReg()
VenCmdEnable()
VenCmdDisable()
Unsupported
ResetDevice()
ResetDevice()
GetDIB()
GetDIB()
Unsupported
Table 4. Command Summary
相關(guān)PDF資料
PDF描述
ASC7611 HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASC7611QS24 HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASC7621 HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASC7621QS24 HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASD05H-12S5 Isolated and Regulated 5 WATT Open Frame DC/DC Converter
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ASC7611 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASC7611QS24 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASC7621 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASC7621QS24 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
ASC-8-2-CB (5-PIN) 制造商:Belden Inc 功能描述:ASC-8-2-CB (5-PIN)