Data Sheet
October 1, 2009
Austin LynxTM II 12V SIP Non-isolated Power Modules:
8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current
LINEAGE POWER
2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
All
VIN
-0.3
15
Vdc
Continuous
Sequencing voltage
All
Vseq
-0.3
VIN,max
Vdc
Operating Ambient Temperature
All
TA
-40
85
°C
(see Thermal Considerations section)
Storage Temperature
All
Tstg
-55
125
°C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
Vo,set ≤ 3.63
VIN
8.3
12.0
14.0
Vdc
Vo,set > 3.63
VIN
8.3
12.0
13.2
Vdc
Maximum Input Current
All
IIN,max
70
Adc
(VIN=2.4V to 5.5V, IO=IO, max )
Input No Load Current
Vo = 0.75Vdc
IIN,No load
40
mA
(VIN = 12.0Vdc, IO = 0, module enabled)
Vo = 5.0Vdc
IIN,No load
100
mA
Input Stand-by Current
All
IIN,stand-by
2.0
mA
(VIN = 12.0Vdc, module disabled)
Inrush Transient
All
I
2t
0.4
A
2s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to
VIN, max, IO= IOmax ; See Test Configurations)
All
20
mAp-p
Input Ripple Rejection (120Hz)
All
30
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a 15A,
time-delay fuse (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s data sheet for further information.