Connectors
for
industrial
equipment
AXW
SPECIFICATIONS
1. Characteristics
2. Materials and surface treatment
3. Applicable cable
DIMENSIONS (Unit: mm)
Item
Specications
Conditions
Electrical
characteristics
Rated current
AWG#22, 24: 3A, AWG#26: 2A, AWG#28: 1A
Rated voltage
250V AC
Breakdown voltage
1,000V AC for 1 min.
Detection current: 1mA
Insulation resistance
Min. 1,000M
Using 500V DC megger
Contact resistance
Max. 20m
Measured based on the HP4338B measurement method of
JIS C 5402
Mechanical
characteristics
Unit removal force
Min. 0.343N {35gf}
Measured by steel-pin-gauge with 0.64
±0.01mm square
(surface roughness 0.1
m)
Composite insertion force
Max. 2.94N {300gf}
× No. of contacts
Life time
characteristics
Insertion and removal life
500 times
Repeat insertion and removal speed of max. 600 times/hour
Environmental
characteristics
Ambient temperature
–50
°C to 105°C
No freezing at low temperatures
Ambient temperature of cables should be considered
Vibration resistance
Double amplitude: 1.52mm
Frequency: 10 to 55Hz (for 3 axes)
No interruption of current longer than 1
s
(Max. carrying current 100mA should be impressed during
the test)
Shock resistance
490m/s2 {50G} (for 3 axes)
No interruption of current longer than 1
s
(Max. carrying current 100mA should be impressed during
the test)
Part name
Materials
Surface treatment
Housing
Glass ber reinforced PBT (UL94V-0)
—
Cover
Semi-cover
Glass ber reinforced PBT (UL94V-0)
—
Hood cover
Glass ber polycarbonate resin (UL94V-0)
Vertical type hood cover (16, 20 contact)
—
Contact
Copper alloy
Contact portion:
Ni plating on base, Au plating on surface
Contact pressure portion:
Ni plating on base, Sn plating on surface
Lead wire bundling metal
(enclosed with vertical type hood cover)
Steel plate
—
Lead wire bundling band
(enclosed with angled type hood cover)
Polyimide resin
—
No.
Cross section area
External gure
Rated current
Remarks
AWG#22
0.3 mm2
1.5 to 1.1 dia.
3A
12 wires/0.18 should used
AWG#24
0.2 mm2
3A
AWG#26
0.14mm2
1.3 to 1.1 dia.
2A
AWG#28
0.08mm2
1A
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://panasonic-electric-works.net/ac
Housing with contacts
Dimension table (mm)
No. of
contacts
Polarity
guide
A
B
10
0
17.3
10.16
10
1
17.3
10.16
14
1
22.4
15.24
16
1
24.9
17.78
20
1
30.0
22.86
26
1
37.6
30.48
30
1
42.7
35.56
34
1
47.8
40.64
40
1
55.4
48.26
50
1
68.1
60.96
60
1
80.8
73.66
64
1
85.9
78.74
General tolerance:
±0.3
14.5
±0.2
14.2
6.0
±0.2
A
B
±0.2
2.54
±0.1
2.54
±0.1
Note) Dimensions of the housing without contact is the same as the right gure.
CAD Data