      20
      Data Device Corporation
      www.ddc-web.com
      BU-65142 SERIES
      V-01/03-0
      Data transfer grant -- active LOW input
      signal from the subsystem that informs
      the RT, when DTREQ is asserted, to start
      the transfer. Once transfer is started,
      DTGRT can be removed.
      TABLE 7. PIN FUNCTIONS
      FUNCTION
      PACKAGE & PIN
      DESCRIPTION
      1
      A9
      (SA4)
      Latched output of the most significant bit
      (MSB) in the subaddress field of the
      command word.
      2
      A7
      (SA2)
      3
      Latched output of the third most signifi-
      cant bit in the subaddress field of the
      command word.
      3
      A5
      (SA0)
      5
      Latched output of the least significant bit
      (LSB) in the subaddress field of the
      command word.
      4
      DB1
      7
      Bi-directional parallel data bus Bit 1
      5
      DB3
      9
      Bi-directional parallel data bus Bit 3
      6
      DB5
      11
      Bi-directional parallel data bus Bit 5
      7
      DB7
      13
      Bi-directional parallel data bus Bit 7
      8
      DB9
      15
      Bi-directional parallel data bus Bit 9
      9
      DB11
      17
      Bi-directional parallel data bus Bit 11
      10
      DB13
      19
      Bi-directional parallel data bus Bit 13
      11
      DB15
      21
      Bi-directional parallel data bus Bit 15
      (MSB)
      12
      BRO ENA
      23
      13
      ADDRE
      (RTAD4)
      25
      Input of the MSB of the assigned termi-
      nal address.
      14
      27
      Input of the 3rd MSB of the assigned
      terminal address.
      15
      ADDRA
      (RTAD0)
      29
      Input of the LSB of the assigned termi-
      nal address.
      16
      RTADERR
      31
      Output signal used to inform subsystem
      of an address parity error. If LOW, indi-
      cates parity error and the RT will not
      respond to any command address to a
      single terminal. It will respond to broad-
      cast commands if BRO ENA is HIGH.
      17
      TXDATA B
      33
      LOW output to the primary side of the
      coupling transformer that connects B
      channel of the 1553 bus.
      18
      NC
      35
      19
      GND B
      37
      Power Supply return connection for the
      B channel transceiver.
      20
      RXDATA B
      39
      22
      21
      A1
      (WC1/
      CWC1)
      A3
      (WC3/
      CWC3)
      76
      78
      Multiplexed address line output. When
      INCMD is LOW or A5 thru A9 are all
      zeroes or all ones (Mode Command), it
      represents the latched output of the 2nd
      LSB in the word count field of the com-
      mand word. When INCMD is HIGH and
      A5 thru A9 are not all zeroes or all ones,
      it represents the 2nd LSB of the current
      word counter.
      Multiplexed address line output. When
      INCMD is LOW or A5 thru A9 are all
      zeroes or all ones (Mode Command), it
      represents the latched output of the 2nd
      MSB in the word count field of the com-
      mand word. When INCMD is HIGH and
      A5 thru A9 are not all zeroes or all ones,
      it represents the 2nd MSB of the current
      word counter.
      Input from the LOW side of the primary
      side of the coupling transformer that con-
      nects to the A channel of the 1553 Bus.
      RXDATA A
      Built-in-Test Word Enable--LOW level output
      pulse (.5s), present when the built-in-test
      word is enabled on the parallel data bus.
      BITEN
      Subsystem Service Request-- Input from
      the subsystem used to control the Service
      Request Bit in the status register. If LOW
      when the status word is updated, the
      Service Request Bit will be set; if HIGH, it
      will be cleared.
      SS REQ
      Illegal Command--active LOW input signal
      from the subsystem, strobed in on the ris-
      ing edge of INCMD. Used to define the
      command word as illegal and to set the
      message error bit in the status register.
      ILLCMD
      Latched output of the T/R bit in the com-
      mand word.
      A10 (T/R)
      TEST 2
      Accept Dynamic Bus Control-- active
      LOW input signal from the subsystem
      used to set the Dynamic Bus Control
      Acceptance bit in the status register if the
      command word was a valid, legal mode
      command for dynamic bus control.
      ADBC
      Data Transfer Request --active LOW out-
      put signal to the subsystem indicating that
      the RT has data for or needs data from
      the subsystem and requests a data trans-
      fer over the parallel data bus. Will stay
      LOW until transfer is completed or transfer
      timeout has occurred.
      DTREQ
      Remote Terminal Failure-- latched active
      LOW output signal to the subsystem to
      flag detection of a remote terminal contin-
      uous self-test failure. Also set if the
      Watchdog Timeout circuit is activated.
      Cleared by the start of the next message
      transmission (status word) and set if prob-
      lem is again detected.
      RTFAIL
      Address line output that is LOW whenever
      the command word is being transferred to
      the subsystem over the parallel data bus,
      and is HIGH whenever data words are
      being transferred.
      (DAT/CMD)
      A LOW level output pulse (166ns) present
      in the middle of every data word transfer
      over the parallel data bus. Used to latch
      or strobe the data into memory, FIFOs,
      registers, etc. Recommended using the
      rising edge to clock data in.
      DTSTR
      HSFAIL
      In-Command -- HIGH level output signal
      used to inform the subsystem that the RT
      is presently servicing a command.
      INCMD
      DTGRT
      48
      36
      50
      35
      52
      34
      54
      33
      56
      32
      58
      31
      60
      30
      62
      29
      64
      28
      66
      27
      68
      26
      70
      25
      72
      24
      23
      74
      FUNCTION
      78-Pin
      Flat-Pack
      TABLE 7. PIN FUNCTIONS (continued)
      DESCRIPTION
      PACKAGE & PIN
      78-Pin
      Flat-
      Pack
      Broadcast enable - when HIGH, this
      input allows recognition of an RT
      address of all ones in the command
      word as a broadcast message. When
      LOW, it prevents response to RT
      address 31 unless it has the assigned
      terminal address.
      Input from the HIGH side of the primary
      side of the coupling transformer that
      connects to the B channel of the 1553
      78-Pin
      QIP
      78-Pin
      QIP
      ADDRC
      (RTAD2)
      Factory test point output-DO NOT USE
      (see note 1)*
      Handshake Fail-- output signal that goes
      LOW and stays LOW whenever the sub-
      system fails to supply DTGRT in time to
      do a successful transfer. Cleared by the
      next NBGT.
      相關(guān)PDF資料
      PDF描述
      BU-65142F2-250K 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDFP78
      BU-65142F2-320W 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CQFP78
      BU-65142F2-370W 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDFP78
      BU-65142F2-530S 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDFP78
      BU-65142F2-850K 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDFP78
      相關(guān)代理商/技術(shù)參數(shù)
      參數(shù)描述
      BU65170G0-100 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Interface IC
      BU65170G0-110 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Interface IC
      BU65170G0-120 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Interface IC
      BU65170G0-200 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Interface IC
      BU65170G0-300 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Interface IC