14
the appropriate I/O signals. Mode command illegalization and
handling are detailed below in TABLE 2.
MODE CODES
The BUS-65142 implements all mode codes applicable to dual-
redundant systems. Mode codes can also be illegalized using
TABLE 2. MODE CODES IMPLEMENTED
DYNAMIC BUS CONTROL (00000)
MESSAGE SEQUENCE = DBC * STATUS
The RT responds with status. If the subsystem wants control of the bus, it must set DBACC in the Configuration Register.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No status response. Bits Set: message error (SW), High Word Count (BIT Word).
3.
bit Set to Zero. No status response. Bits set: message error (S/W), T/R Error (BIT Word).
4. Zero
bit and Broadcast Address. No status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code,
T/R Error (BIT Word).
5. Broadcast Address. No status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code (BIT Word).
R
T/
R
T/
SYNCHRONIZE WITHOUT DATA WORD (00001)
MESSAGE SEQUENCE = SYNC * STATUS
The RT responds with status. If sent as a broadcast, the broadcast receive bit will be set and status response suppressed.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word)
3.
bit Set to Zero. No statue response. Bits set: message error (S/W), T/R Error (BIT Word).
4. Zero
bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code,
T/R Error (BIT Word).
R
T/
R
T/
STATUS WORD (00010)
MESSAGE SEQUENCE = TRANSMIT WORD * STATUS
The status and BIT word registers are not altered by this command and contain the status from the previous command.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word)
3.
bit Set to Zero. No statue response. Bits set: message error (S/W), T/R Error (BIT Word).
4. Zero
bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code,
T/R Error (BIT Word).
5. Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), T/R Error (BIT Word).
R
T/
R
T/
INITIATE SELF-TEST (00011)
MESSAGE SEQUENCE = SELF TEST * STATUS
The RT responds with a status word. If the command was broadcast, the broadcast received bit is set and status transmission suppressed.
Short-loop test is initiated on the status word transmitted. If the test fails, an RT fail flag is set.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word)
3.
bit Set to Zero. No statue response. Bits set: message error (S/W), T/R Error (BIT Word).
4. Zero
bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), T/R Error (BIT Word).
5. Faulty Test. Bits set: terminal flag (S/W),
Loop Test Fail, Current 1553 Bus (A or B) Loop Test Fail (BIT Word)
B
/
A
R
T/
R
T/
TRANSMITTER SHUTDOWN (00100)
MESSAGE SEQUENCE =SHUTDOWN * STATUS
This command is only used with dual redundant bus systems. The RT responds with status. At the end of the status transmission, the RT inhibits
any further transmission from the dual redundant channel. Once shutdown, the transmitter can only be reactivated by OVERRIDE TRANSMITTER
SHUTDOWN or RESET RT commands.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No statue response. Bits Set: message error (SW), High Word Count (BIT Word)
3.
bit Set to Zero. No statue response. Bits set: message error (S/W), T/R Error (BIT Word).
4. Zero
bit and Broadcast Address. No statue response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code,
T/R Error (BIT Word).
R
T/
R
T/
* = Status Response Time
相關PDF資料
PDF描述
BUS-65145-250Z PROGRAMMABLE QUAD BIPOLAR OPERATIONAL AMPLIFIERS
BUS-65145-260 Low power quad operational amplifier
BUS-65145-260K Low power quad operational amplifier
BUS-65145-260L Low power quad operational amplifier
BUS-65145-260Q Low power quad operational amplifier
相關代理商/技術參數(shù)
參數(shù)描述
BU-S802 制造商:Fuji Electric 功能描述:
BU-S803 制造商:Fuji Electric 功能描述:
BUS98 制造商:ONSEMI 制造商全稱:ON Semiconductor 功能描述:SITCHMODE Series NPN Silicon Power Transistors
BUS98/D 制造商:未知廠家 制造商全稱:未知廠家 功能描述:SWITCHMODE? Series NPN Silicon Power Transistors
BUS98A 制造商:ONSEMI 制造商全稱:ON Semiconductor 功能描述:SITCHMODE Series NPN Silicon Power Transistors