World Modem FAX Page 15 of 62 2005, Copeland Communications, Inc. World Modem FAX Datasheet Rev 1.0 Basic AT Command Set (Command Defa" />
參數(shù)資料
型號(hào): CC-2417K2-CS5
廠商: Copeland Communications Inc
文件頁數(shù): 7/62頁
文件大?。?/td> 0K
描述: MODEM FAX 14.4K 5V
標(biāo)準(zhǔn)包裝: 30
數(shù)據(jù)格式: V.21,V.22,V.23,Bell 103
波特率: 14.4k
電源電壓: 4.2 V ~ 7 V
安裝類型: 表面貼裝
封裝/外殼: 模塊
包裝: 散裝
配用: 539-1002-ND - KIT EVALUATION WORLD MODEM II
Data Sheet
World Modem FAX
Page 15 of 62
2005, Copeland Communications, Inc.
World Modem FAX Datasheet Rev 1.0
Basic AT Command Set (Command Defaults in Bold)
Command
Action
$
Display AT command mode settings
A
Answer incoming call
A/
Re-execute last command. This is the only command not preceded by "AT" or followed by a
<CR>
Dial, followed by 1 or more dial command modifiers, manually dials a phone number
Modifier
Function
! or &
Flash hook switch for FHT (U4F) ms (default: 500 ms)
, or <
Pause before continuing for S8 seconds (default: 2
seconds)
;
Return to AT command mode
@
Wait for silence.
G
Polarity reversal detect. By placing the "G" character in
the dial string (i.e. ATDTG1), the modem will monitor the
telephone line for polarity reversals. If a busy tone is
detected, the modem will report "POLARITY
REVERSAL" if a polarity reversal was detected or "NO
POLARITY REVERSAL" if a polarity reversal was not
detected. In each case, the result code is followed by
"OK". If the S7 timeout occurs before a busy tone is
detected, the modem will report "NO CARRIER".
Polarity reversal monitoring begins after the last digit is
dialed and ends when the busy tone is detected or S7
timeout occurs.
L
Redial last number.
P
Pulse (rotary) dialing)
T
Tone (DTMF) dialing
Dn
W
Wait for dial tone before continuing for S14 seconds
(default: 12 seconds). Blind dialing modes X0, X1, and
X3 do not affect the W command. If the DOP bit (U7A,
bit 7) is set, the "ATDTW" command will cause the
modem to pause dialing and either report an "OK" if a
dial tone is detected or "NO DIALTONE" if a dial tone is
not detected.
En
Local DTE echo
E0
Disable
E1
Enable
Hn
Hook switch
H0
Go on-hook (hang up modem).
H1
Go off-hook.
相關(guān)PDF資料
PDF描述
VE-26J-IX-F1 CONVERTER MOD DC/DC 36V 75W
VE-26B-IX-F3 CONVERTER MOD DC/DC 95V 75W
CC-2434K2-CS MODEM FAX 33K 3.3V
VE-26B-IX-F2 CONVERTER MOD DC/DC 95V 75W
VE-26B-IX-F1 CONVERTER MOD DC/DC 95V 75W
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CC2418 制造商:Belden Inc 功能描述:2 PAIR CAT 5E + 2 COND. 18 AWG CM
CC2-4-2/0#4 制造商:Thomas & Betts 功能描述:Cable Accessories Exothermic Welding Reusable Graphite Mold
CC2-4-2/02/0 制造商:Thomas & Betts 功能描述:CABLE TO CABLE TTEE
CC2420 制造商:TI 制造商全稱:Texas Instruments 功能描述:2.4 GHz IEEE 802.15.4 / ZigBee-ready RF Transceiver
CC2420/T&R 制造商:未知廠家 制造商全稱:未知廠家 功能描述:2.4 GHz IEEE 802.15.4 / ZigBee-ready RF Transceiver