    150 Watt DC-DC Converters
    K Series
    Edition 01/01.2000
    25/31
    RV: Current limiting resistance = RS + RI = 15
    [A]
    Ui/RV
    <30
    t [ms]
    Capacitor
    Ci
    fully charged
    Normal operation
    (current limiting
    circuit is fully
    conducting)
    0
    Ii = Pi/Ui
    11039
    Fig. 26
    Inrush current with option E
    Table 16: Inrush current characteristics with option E
    Characteristics
    CK
    DK
    EK
    Unit
    Ui nom, Io nom
    Input voltage
    60
    110
    220
    V
    Iinr p
    Peak inrush
    6.8
    7.4
    14.6
    A
    current
    tinr
    Inrush current
    18
    14
    16
    ms
    duration
    Ui max, Io nom
    Input voltage
    140
    220
    380
    V
    Iinr p
    Peak inrush
    9.3
    14.5
    25.3
    A
    current
    tinr
    Inrush current
    20
    14
    12
    ms
    duration
    Precaution: Subsequent switch-on cycles at start-up
    are limited to max. 10 cycles during the first 20 seconds
    (cold unit) and at continuing on/off (
    TC =95°C) max. 1
    cycle every 8 sec.
    Input
    Filter
    Control
    Converter
    FET
    Ci
    RI
    RS
    10017
    Fig. 25
    Option E block diagram
    P Potentiometer
    The potentiometer provides an output voltage adjustment
    range of +10/–60% of
    Uo nom and is accessible through a
    hole in the front cover. This feature enables compensation
    of voltage drops across the connector and wiring. Option P
    is not recommended if units are connected in parallel.
    Option P excludes the R-function. With double output units
    both outputs are affected by the potentiometer setting (dou-
    bling the voltage setting if the outputs are in series).
    If the output voltages are increased above
    Uo nom via R-in-
    put control, option P setting, remote sensing or option T, the
    output current(s) should be reduced accordingly so that
    Po nom is not exceeded.
    Description of Options
    Table 15: Survey of options
    Option
    Function of Option
    Characteristics
    -9
    Extended operational ambient temperature range
    TA = –40°C...71°C
    E
    Electronic inrush current limitation circuitry
    Active inrush current limitation for CK, DK, EK
    P 1
    Potentiometer for fine adjustment of output voltage
    Adjustment range +10/–60% of
    Uo nom excludes R input
    D 2
    Input and/or output undervoltage monitoring circuitry
    Safe data signal output (Versions D0...DD)
    V 2 3
    Input (and output) undervoltage monitoring circuitry
    ACFAIL signal according to VME specs (Versions V0, V2, V3)
    T
    Current sharing
    Interconnect T-pins if paralleling outputs (5 units max.)
    B1/B2
    Cooling plate
    Replaces standard heat sink, allowing direct chassis-mounting
    1 Function R excludes option P and vice versa.
    2 Option D excludes Option V and vice versa .
    3 Only available if main output voltage U o1 = 5.1.
    -9 Extended Temperature Range
    Option -9 extends the operational ambient temperature
    range from –25...71
    °C (standard) to –40...71°C. The power
    supplies provide full nominal output power with convection
    cooling. Option -9 excludes inrush current limitation by
    NTC.
    E Inrush Current Limitation
    CK/DK/EK types may be supplemented by an electronic
    circuit (option E, replacing the standard built-in NTC) to
    achieve an enhanced inrush current limiting function (not
    available with AK/BK/FK types).
    If fitted with option E (inrush current limitation) together with
    option D6, input voltage monitoring, the CK units meet the
    CEPT/ETSI standards for 48 V DC supply voltages accord-
    ing to prETS 300132-2, version 4.2, date 9312. Option D6,
    externally adjustable via potentiometer, is necessary to dis-
    able the converter at input voltages below actual service
    voltage ranges, avoiding an excessive input current
    when the input voltage is raised slowly according to
    prETS 300132-2. Option D6 threshold level should be ad-
    justed to 36.0...40.5 V for 48 V nominal supply systems or
    44.0...50.0 V for 60 V nominal supply systems (refer also to
    description of option D). The D output should be connected
    to the inhibit input. Please contact Power-One if applica-
    tions do not permit potentiometer setting.
    相關(guān)PDF資料
    PDF描述
    CK1601-9PD8T 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
    CK2320-7EPD7TB1 2-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
    CK2320-7PB2 2-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
    CK2320-7PDDB2 2-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
    CK2320-7RD5TB2 2-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    CK1601-9RT 制造商:Power-One 功能描述:
    CK1608100M-T 功能描述:固定電感器 INDCTR HICUR MLTLYR 0603 10uH 20% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm
    CK-1608-100MTK 功能描述:固定電感器 10uH 5mA 20% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm
    CK16084R7M-T 功能描述:固定電感器 INDCTR HICUR MLTLYR 0603 4.7uH 20% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm
    CK-1608-4R7MTK 功能描述:固定電感器 4.7uH 15mA 20% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm