COM7900T Series
ELECTRICAL CHARACTERISTICS -5 Volt
V
IN
= -10V, I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
V
OUT
T
A
= 25°C
-4.9
-5.1
V
V
IN
= -7.5V to -20V
-4.8
-5.2
V
Line Regulation
V
RLINE
V
IN
= -7.5V to -20V
12
m V
(Note 1)
25
m V
V
IN
= -8.0V to -12V
5
m V
12
m V
Load Regulation
V
RLOAD
I
O
= 5mA to 1.5 Amp
20
m V
(Note 1)
25
m V
I
O
= 250mA to 750 mA
15
m V
30
m V
Standby Current Drain
I
SCD
2.5
m A
3.0
m A
Standby Current Drain
D
I
SCD
V
IN
= -7.0V to -20V
0.4
m A
Change With Line
(Line)
Standby Current Drain
D
I
SCD
I
O
= 5mA to 1000mA
0.4
m A
Change With Load
(Load)
Dropout Voltage
V
D O
D
V
OUT
= 100mV, I
O
=
1.0A
2.5
V
Peak Output Current
I
O (pk)
T
A
= 25°C
1.5
3.3
A
Short Circuit Current
I
DS
V
IN
= -35V
1.2
A
(Note 2)
2.8
A
Ripple Rejection
D
V
IN
f =120 Hz,
D
V
IN
= -10V
63
dB
D
V
OUT
(Note 3)
60
dB
Output Noise Voltage
N
O
T
A
= 25°C, f =10 Hz to 100KHz
40
μV/V
(Note 3)
RMS
Long Term Stability
D
V
OUT
T
A
= 25°C, t = 1000 hrs.
75
m V
(Note 3)
D
t
ELECTRICAL CHARACTERISTICS -12 Volt
V
IN
= -19V,I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
V
OUT
T
A
= 25°C
-11.76
-12.24
V
V
IN
= -14.5V to -27V
-11.6
-12.4
V
Line Regulation
V
RLINE
V
IN
= -14.5V to -27V
20
m V
(Note 1)
50
m V
V
IN
= -16V to -22V
10
m V
30
m V
Load Regulation
V
RLOAD
I
O
= 5mA to 1.5 Amp
32
m V
(Note 1)
60
m V
I
O
= 250mA to 750 mA
16
m V
30
m V
Standby Current Drain
I
SCD
3.5
m A
4.0
m A
Standby Current Drain
D
I
SCD
V
IN
= -14.5V to -27V
0.8
m A
Change With Line
(Line)
Standby Current Drain
D
I
SCD
I
O
= 5mA to 1000mA
0.5
m A
Change W ith Load
(Load)
Dropout Voltage
V
D O
D
V
OUT
= 100mV,I
O
=
1.0A
1.8
V
Peak Output Current
I
O (pk)
T
A
= 25°C, I
O
= 5mA to 1A
1.5
3.3
A
Short Circuit Current
I
DS
V
IN
= -35V
1.2
A
(Note 2)
2.8
A
Ripple Rejection
D
V
IN
f =120 Hz,
D
V
IN
= -10V
56
dB
D
V
OUT
(Note 3)
53
dB
Output Noise Voltage
N
O
T
A
= 25°C, f =10 Hz to 100KHz
40
μV/V
(Note 3)
RMS
Long Term Stability
D
V
OUT
T
A
= 25°C, t = 1000 hrs.
120
m V
(Note 3)
D
t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The denotes the specifications which apply over the full operating temperature range.