![](http://datasheet.mmic.net.cn/170000/CQ2540-7P_datasheet_8597875/CQ2540-7P_11.png)
Cassette Style
DC-DC Converters
Q Series
Edition 5/5.2000
11/25
Table 5a: Output data for double output modules with output 1 and output 2 in symmetrical configuration
Output
BQ...GQ 2320
BQ...GQ 2540
12 V/12 V
15 V/15 V
Characteristics
Conditions
Output 1
Output 2
Output 1
Output 2
min
typ max
min
typ max
min
typ max
min
typ max
Unit
Uo
Output voltage 1
Ui nom, Io nom
11.94
12.06
11.82
12.18
14.93
15.08
14.78
15.23
V
Uow
Worstcase output
Ui min...Ui max
11.82
12.18
see
Output
14.78
15.23
see
Output
voltage
TC min...TC max
voltage regulation
Uo P
Overvoltage limitation
Io = 0...Io max
13.5
15.0
17.0
19.0
of second control loop
Io
Output current 2
Ui min...Ui max
0.8
9.2
0.8
9.2
0.6
7.4
0.6
7.4
A
Io nom
Nominal output current 3
TC min...TC max
8.0
6.6
Io L
Output current limit 2
10.5 11.0 13.0
8.4
8.8 10.4
8.4
8.8 10.4
uo
Output
Switch. frequ.
Ui nom, Io nom
10
20
10
20
10
25
10
25
mVpp
voltage
Total
IEC/EN 61204
20
40
20
40
15
40
15
40
noise 4
BW = 20 MHz
Po
Output power 1
Ui min...Ui max
130
W
TC min...TC max
uo d 5
Dynamic
Voltage
Ui nom, DIo1 =
±300
±350
±300
±350
mV
load
deviation
1/2
1/4 I
o nom
td
regulation
Recovery
Io2 = 1/2 Io nom
120
100
s
time
IEC/EN 61204 4
Uo tr
Output voltage trimming
Ui min...Ui max
5.5
13.2
8.0
16.5
V
range 6
Io min...Io max
10.8
13.2
13.5
16.5
TC min...TC max
Table 5b: Output data for double output modules with output 1 and output 2 in symmetrical configuration
Output
BQ...GQ 2660
24 V/24 V
Characteristics
Conditions
Output 1
Output 2
min
typ max
min
typ max
Unit
Uo
Output voltage 1
Ui nom, Io nom
23.88
24.12
23.64
24.36
V
Uow
Worstcase output
Ui min...Ui max
23.64
24.36
see
Output
voltage
TC min...TC max
voltage regulation
Uo P
Overvoltage limitation
Io = 0...Io max
27.5
30.0
of second control loop
Io
Output current 2
Ui min...Ui max
0.4
5.1
0.4
5.1
A
Io nom
Nominal output current 3
TC min...TC max
4.4
Io L
Output current limit 2
5.8
6.1
7.7
5.8
6.1
7.7
uo
Output
Switch. frequ.
Ui nom, Io nom
60
90
60
90
mVpp
voltage
Total
IEC/EN 61204
70
100
70
100
noise 4
BW = 20 MHz
Po
Output power 1
Ui min...Ui max
140
W
TC min...TC max
uo d 5
Dynamic
Voltage
Ui nom, DIo1 =
±550
±400
mV
load
deviation
1/2
1/4 I
o nom
td
regulation
Recovery
Io2 = 1/2 Io nom
100
s
time
IEC/EN 61204 4
Uo tr
Output voltage trimming
Ui min...Ui max
14.0 7
26.4
V
range 6
Io min...Io max
21.6
26.4
TC min...TC max
1 If the output voltages are increased above Uo nom through R-
input control, option P setting or remote sensing, the output
power should be reduced accordingly so that
Po max and TC max
are not exceeded.
2 See: Output Current Limitation and Output power at reduced
temperature.
3 In parallel and symmetrical configuration, Io nom = Io1 nom + Io2 nom.
4 See: Technical Information: Measuring and Testing.
5 Recovery time until Uo remains within ±1% of Uo, see: Dynamic
load regulation.
6 Upper row represents setting via R-input, lower row option P
range.
7 For DQ 2660: Uo tr min =19 V.