D4DL
D4DL
3
Specifications
Approved Standard Ratings
TüV (EN60947-5-1)
Item
LED
type
Neon lamp
type
AC-15
3 A
250 V
Utilization category
Rated operating current (I
e
)
Rated operating voltage (U
e
)
AC-15
6 A
1
15 V
Note:
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Use a 10-A fuse type gI or gG as a short-circuit protection device that conforms to IEC269.
Rated
voltage
Carry current
Ca y cu e
Current (A)
Voltage
Make
Break
Make
Break
120 V
AC
240 V
AC
10A
60
30
6
3
7,200
, 00
720
Characteristics
Degree
of protection (see note 2)
Life expectancy (see note 3)
IP65 (EN60947-5-1)
Mechanical:
1,000,000 times min.
Electrical:
500,000 times min.
Operating speed
Operating frequency
Rated frequency
Positive opening force (see note 4)
Positive opening travel (see note 4)
Holding force
Insulation resistance
Rated insulation voltage (U
i
)
Conventional enclosed thermal current
(I
the
)
Rated impulse voltage (U
imp
)
0.05 to 0.5 m/s
30 operations/minute max.
50/60 Hz
58.84 N {6 kgf} min. (EN60947-5-1)
10 mm min. (EN60947-5-1)
500 N {51 kgf} min. (GS-ET
-19)
100 M
min. (at 500 VDC)
300 V (EN60947-5-1)
10 A (EN60947-5-1)
Between terminals of same or dif
ferent polarity
, each terminal and ground, and each
terminal and non-current-carrying metal part: 4 kV
Between the solenoid and non-current-carrying metal part: 0.8 kV for 24 VDC solenoid,
2.5 kV for 1
10 V
AC solenoid, and 4 kV for 230 V
AC solenoid (EN60947-5-1)
100 A (EN60947-5-1)
3 (EN60947-5-1)
Class II (double insulation)
1,500 V max. (EN60947-5-1)
25 m
max. (initial value)
Malfunction:
10 to 55 Hz, 0.75-mm single amplitude
Mechanical:
1,000 m/s
2
(100G) min.
Malfunction:
300 m/s
2
(30G) min.
Operating: –10
°
C to 55
°
C with no icing
Operating: 95% max.
Approx. 340 g (D4DL-1CF
A-B)
Glass-fiber reinforced thermoplast, self-extinguishing
Stainless steel
Conditional short-circuit current
Pollution degree (operating environment)
Protection against electric shock
Switching overvoltage
Contact resistance
V
ibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Material
a e a
Body and actuator flange
Actuator
Note:
1.
The above values are initial values.
2. Although the switch box is protected from dust or water penetration, do not use the D4DL in places where foreign material may
penetrate through the key hole on the head, otherwise switch damage or malfunctioning may occur
.
3. The
above mechanical or electrical life is ensured at an ambient temperature of 5
°
C to 35
°
C and an ambient humidity of 40% to 70%.
4. These
values must be satisfied to ensure safe operation.