190
Special Features
60 Watts
DAS60
Electrical Specs
CE Mark EMC & LVD
Universal AC input
Fully regulated output
Overload and short circuit protection
Thermal protection
Blue Angel compliance
Constant voltage
High efficiency
High MTBF
IEC320 AC receptacle, 3 pin (type C14)
Built in EMI filter (CISPR 22 Class B)
LED power good indicator
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI/RFI
90 - 264 VAC (wide range)
47 - 63 Hz
50A @ 230 VAC, cold start @ 25C
1.5A rms @ 90 VAC; 0.5A @ 264VAC
>80% @ full load typical, @115VAC
FCC Part 15, Subpart B Class B & EN55022
(CISPR 22) Class B
Safety ground
leakage current
300μA max. @ 50/60 Hz, 230 VAC input
Output
Voltage (Vo)
Voltage regulation
Maximum Power (Po)
Hold-up time
Overvoltage protection
48V
± 2% @ constant voltage mode
60W
20 ms. typical at full load @ 115VAC
25% above nominal output maximum.
Latching type, recycle AC to reset.
Output short circuit protection auto recover.
Overload protected @ 150% above maximum
rating.
Overload protection
Overtemperature
protection
Cable/connector
barrel type
Auto recovery
DC cable with 2.5 mm center plug
DC plug center +v
DC plug outer -v
Operating temperature: -5°C to +50°C ambient
Storage temperature: -40°C to +70°C
Electromagnetic susceptability; design to meet
EN61000-4,-2,-4,-5,-6,-11, level 3
Humidity: Operating; non-condensing; 10% to
90% RH
Vibration: Three orthogonal axes, sweep at 1
oct/min. 5 min. dwell at four major resonances 2G
peak 8 Hz to 500 Hz, operational
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
UL
CUL
NEMKO
TUV
CB
CE
60950
60950
60950
60950
Certificate and report
EMC & LVD
Environmental
Safety
Total Power:
Input Voltage:
# of Outputs:
60 Watts
90-264 VAC
Single