6
Electrical Specifications
T
A
= Over Operating Temperature Range, V+ = +15V, V- = -15V, GND = 0V, V
EN
= 2.4V,
Unless Otherwise Specified
PARAMETER
TEST CONDITIONS
“A” SUFFIX
“B” AND “C” SUFFIX
UNITS
MIN
(NOTE 3)
TYP
MAX
MIN
(NOTE 3)
TYP
MAX
DIGITAL INPUT CHARACTERISTICS
Address Input Current, Input
Voltage High, I
AH
V
A
= 2.4V
V
A
= 15V
V
EN
= 2.4V
V
EN
= 0V
-30
-
-
-
-
-
μ
A
μ
A
μ
A
μ
A
-
-
30
-
-
-
Address Input Current Input
Voltage Low, I
AL
V
A
= 0V
-30
-
-
-
-
-
-30
-
-
-
-
-
ANALOG SWITCH CHARACTERISTICS
Analog Signal Range,
V
ANALOG
Drain-Source ON
Resistance, r
DS(ON)
(Note 7)
-15
-
+15
-
-
-
V
Sequence Each
Switch ON
V
AL
= 0.8V
V
AH
= 2.4V
V
EN
= 0V
I
S
= -200
μ
A, V
D
= +10V
I
S
= -200
μ
A, V
D
= -10V
-
-
500
-
-
-
-
-
500
-
-
-
Source OFF Leakage
Current, I
S(OFF)
V
S
= +10V, V
D
= -10V
V
S
= -10V, V
D
= +10V
-
-
50
-
-
-
nA
-50
-
-
-
-
-
nA
Drain OFF Leakage Current,
I
D(OFF)
DG506A
V
EN
= 0V
V
S
= -10V, V
D
= +10V
V
S
= +10V, V
D
= -10V
V
S
= -10V, V
D
= +10V
V
S
= +10V, V
D
= -10V
V
S
= -10V, V
D
= +10V
V
S
= +10V, V
D
= -10V
-
-
300
-
-
-
nA
-300
-
-
-
-
-
nA
DG507A
-
-
200
-
-
-
nA
-200
-
-
-
-
-
nA
DG509A
-
-
100
-
-
-
nA
-100
-
-
-
-
-
nA
Drain ON Leakage Current,
I
D(ON)
DG506A
(Note 6)
Sequence Each
Switch ON
V
AL
= 0.8V
V
AH
= 2.4V
V
D
= V
S(ALL)
= +10V
V
D
= V
S(ALL)
= -10V
V
D
= V
S(ALL)
= +10V
V
D
= V
S(ALL)
= -10V
V
D
= V
S(ALL)
= +10V
V
D
= V
S(ALL)
= -10V
-
-
300
-
-
-
nA
-300
-
-
-
-
-
nA
DG507A
-
-
200
-
-
-
nA
-200
-
-
-
-
-
nA
DG509A
-
-
100
-
-
-
nA
-100
-
-
-
-
-
nA
POWER SUPPLY CHARACTERISTICS
Positive Supply Current, I+
V
EN
= 5.0V, V
A
= 0V
-3.2
-
4.5
-
-
-
mA
Negative Supply Current, I-
-3.2
-
4.5
-
-
-
mA
Positive Standby Supply Current, I+
V
EN
= 0V, V
A
= 0V
-3.2
-
4.5
-
-
-
mA
Negative Standby Supply Current, I-
-3.2
-
4.5
-
-
-
mA
NOTES:
3. Typical values are for design aid only, not guaranteed and not subject to production testing.
4. The algebraic convention whereby the most negative value is a minimum, and the most positive value is a maximum, is used in this data sheet.
5. Off isolation = 20Log |V
S
|/|V
D
|, where V
S
= input to Off switch, and V
D
= output due to V
S
.
6. I
D(ON)
is leakage from driver into “ON” switch.
7. Parameter not tested. Parameter guaranteed by design or characterization.
DG506A, DG507A, DG509A