Document Number: 67185
S11-0345-Rev. C, 07-Mar-11
www.vishay.com
3
Vishay Siliconix
DG9454
Notes:
a. VIN = input voltage to perform proper function.
b. Room - 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
SPECIFICATIONS FOR UNIPOLAR SUPPLIES
Parameter
Symbol
Test Conditions
Unless Otherwise Specified
VCC = + 12 V, VL = 2.7 V
VIN(A, B, C and enable) = 1.6 V, 0.5 V
a
Temp.b
Typ.c
- 40 °C to + 125 °C - 40 °C to + 85 °C
Unit
Min.d
Max.d
Min.d
Max.d
Analog Switch
Switch Off
Leakage Current
IS(off)
V+ = + 13.2 V, VL = 2.7 V
VD = 1 V/12.2 V, VS = 12.2 V/1 V
Room
Full
± 0.02
- 1
- 50
1
50
- 1
- 5
1
5
nA
ID(off)
Room
Full
± 0.02
- 1
- 50
1
50
- 1
- 5
1
5
Channel On
Leakage Current
ID(on)
V+ = + 13.2 V, VL = 2.7 V
VD = VS = 1 V/12.2 V
Room
Full
± 0.02
- 1
- 50
1
50
- 1
- 5
1
5
Digital Control
Logic Low Input Voltage
VL = 2.7 V
Full
0.5
V
Logic High Input Voltage
VINH
Full
1.6
Logic Low Input Current
IL
VIN A0, A1, A2 and enable
under test = 0.5 V
Full
0.01
- 1
1
- 1
1
A
Logic High Input current
IH
VIN A0, A1, A2 and enable
above test = 1.6 V
Full
0.01
- 1
1
- 1
1
Dynamic Characteristics
Transition Time
tTRANS
RL = 300 , CL = 35 pF
see figure 1, 2, 3
Room
Full
80
135
205
135
170
ns
Enable Turn-On Time
tON(EN)
Room
Full
115
180
250
180
215
Enable Turn-Off Time
tOFF(EN)
Room
Full
46
110
180
110
145
Break-Before-Make
Time Delay
tD
Room
Full
37
12
Charge Injectione
Q
CL = 1 nF, RGEN = 0 , VGEN = 0 V
Full
0.86
pC
Off Isolatione
OIRR
f = 1 MHz,
RL = 50 , CL = 5 pF
100 kHz
Room
< - 90
dB
1 MHz
Room
- 80
10 MHz
Room
- 61
Crosstalke
XTALK
100 kHz
Room
< - 90
1 MHz
Room
- 81
10 MHz
Room
- 65
Bandwidth, - 3dBe
BW
RL = 50
Room
540
MHz
Source Off Capacitancee
CS(off)
f = 1 MHz
Room
2
pF
Drain Off Capacitancee
CD(off)
Room
3
Channel On Capacitancee
CD(on)
Room
6
Total Harmonic Distortione
THD
Signal = 1 VRMS,
20 Hz to 20 kHz, RL = 600
Room
0.01
%
Power Supply
Power Supply Range
I+
VIN(A, B, C and enable) = 0 V or + 12 V
Room
Full
0.05
1
10
1
10
A
Ground Current
IGND
Room
Full
0.05
- 1
- 10
- 1
- 10
Logic Supply Current
IL
VL = 2.7 V
Room
Full
0.05
1
10
1
10