Package Outline
NOTES: 1. Tolerance on 3 place decimals
±
.010(.25) except as noted.
2. Dimensions in inches over mm.
DML-6B-10G
2 to18 GHz/ +10 to+13 dBmLO/ Low ConvLoss/ WdebandIF/ HermeticPkgwithRemovabeSMA
TRPLEBALANCED MIXER
For further information contact
MERRMAC/ 41 FairfiedP., West Caldwel, NJ, 07006 /
973
-575-1300 / FAX
973
-575-0531
PRINCIPAL SPECIFICATIONS
IF
Conversion
Range,
Loss, SSB, dB,
dBm, Nom. GHz
Max.
+10 to+ 13 0.5 - 6
8.5
0.01 - 8
9.5
All specifications are as measured in a 50
system, at nominal LO Power, in a down converter application.
RF/LO
Frequency,
GHz
2 - 18
LO Drive
Range,
Isolation,
L-R, dB,
Min. Typ. Min.
20
30
Isolation,
L-X, dB,
Isolation,
R-X, dB,
VSWR,
Typ.
LO
2.0:1 2.0:1
Model
Number
DML-6B-10G
Typ.
6.5
6.5
Typ. Min. Typ.
30
20
RF
20
30
General Notes:
1. The DML-6B-10G Triple Balanced Mixer covers the frequency range
of 2 to 18 GHz and is optimized for wide IF bandwidth, low loss and
broad RF/LO bandwidth. The hermetic removable SMA package is
used for performance testing and reliability.
2. Merrimac offers a broad selection of Balanced Mixers ideal for a
variety of signal processing functions from 20 kHz to 20 GHz and for
applications ranging from routine to very special.
3. All Merrimac mixers comply with MIL-M-28837 and may be supplied
screened for compliance with additional specifications for military and
space applications requiring the highest reliability.
GENERAL SPECIFICATIONS
Third Order Input Intercept: +15 dBm typ.
Noise Figure:
Within
±
1 dB of
Conversion Loss
+8 dBm typ.
1 dB Compression Point:
(Referenced to Input)
1 dB Desensitization Point: +7 dBm typ.
(Referenced to Input)
Polarity Sense:
DC Offset Voltage:
Weight with SMA, nom:
Operating Temperature:
Positive
5 - 15 mV typ.
0.7 oz (20 g)
– 55° to +85°C
23Feb96