READ/WRITE TIMING DIAGRAM (cont’d) Figure 6
Write-zero Time Slot
60s ≤ tLOW0< tSLOT< 120s
1s ≤ tREC< ∞
Read-data Time Slot
60s ≤ tSLOT < 120s
1s ≤ tLOWR< 15s
0 ≤ tRELEASE< 45s
1s ≤ tREC< ∞
tRDV= 15s
tSU < 1s
CRC GENERATION
To validate the data transmitted from the DS2401, the bus master may generate a CRC value from the
data as it is received. This generated value is compared to the value stored in the last 8 bi ts of the
DS2401. If the two CRC values match, the transmission is error-free.
The equivalent polynomial function of this CRC is: CRC = x8 + x5 + x4 + 1. Additional information about
the Maxim 1-Wire CRC is available in Application Note 27.
CUSTOM DS2401
Customization of a portion of the unique 48-bit serial number by the customer is available. Maxim will
register and assign a specific customer ID in the 12 most significant bits of the 48-bit field. The next most
significant bits are selectable by the customer as a starting value, and the least significant bits are non-
selectable and will be automatically incremented by one. Certain quantities and conditions apply for these
custom parts. Contact your Maxim sales representative for more information.