參數(shù)資料
型號: DS323
廠商: Spansion Inc.
英文描述: 32 Megabit (4 M x 8-Bit/2 M x 16-Bit) CMOS 1.8 Volt-only, Simultaneous Operation Flash Memory
中文描述: 32兆位(4個M × 8位/ 2米x 16位),1.8伏的CMOS只,同時作業(yè)快閃記憶體
文件頁數(shù): 24/52頁
文件大?。?/td> 604K
代理商: DS323
May 15, 2002
Am29DS32xG
23
A D V A N C E I N F O R M A T I O N
again read array data with the same exception. See
the Erase Suspend/Erase Resume Commands sec-
tion for more information.
The system
must
issue the reset command to return a
bank to the read (or erase-suspend-read) mode if DQ5
goes high during an active program or erase opera-
tion, or if the bank is in the autoselect mode. See the
next section, Reset Command, for more information.
See also Requirements for Reading Array Data in the
Device Bus Operations section for more information.
The Read-Only Operations table provides the read pa-
rameters, and Figure 13 shows the timing diagram.
Reset Command
Writing the reset command resets the banks to the
read or erase-suspend-read mode. Address bits are
don’t cares for this command.
The reset command may be written between the se-
quence cycles in an erase command sequence before
erasing begins. This resets the bank to which the sys-
tem was writing to the read mode. Once erasure be-
gins, however, the device ignores reset commands
until the operation is complete.
The reset command may be written between the
sequence cycles in a program command sequence
before programming begins. This resets the bank to
which the system was writing to the read mode. If the
program command sequence is written to a bank that
is in the Erase Suspend mode, writing the reset
command returns that bank to the erase-sus-
pend-read mode. Once programming begins, how-
ever, the device ignores reset commands until the
operation is complete.
The reset command may be written between the se-
quence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command
must be written to return to the read mode. If a bank
entered the autoselect mode while in the Erase Sus-
pend mode, writing the reset command returns that
bank to the erase-suspend-read mode.
If DQ5 goes high during a program or erase operation,
writing the reset command returns the banks to the
read mode (or erase-suspend-read mode if that bank
was in Erase Suspend).
Autoselect Command Sequence
The autoselect command sequence allows the host
system to access the manufacturer and device codes,
and determine whether or not a sector is protected.
Table 14 shows the address and data requirements.
This method is an alternative to that shown in Table 7,
which is intended for PROM programmers and re-
quires V
ID
on address pin A9. The autoselect com-
mand sequence may be written to an address within a
bank that is either in the read or erase-suspend-read
mode. The autoselect command may not be written
while the device is actively programming or erasing in
the other bank.
The autoselect command sequence is initiated by first
writing two unlock cycles. This is followed by a third
write cycle that contains the bank address and the au-
toselect command. The bank then enters the autose-
lect mode. The system may read at any address within
the same bank any number of times without initiating
another autoselect command sequence:
A read cycle at address (BA)XX00h (where BA is
the bank address) returns the manufacturer code.
A read cycle at address (BA)XX01h in word mode
(or (BA)XX02h in byte mode) returns the device
code.
A read cycle to an address containing a sector ad-
dress (SA) within the same bank, and the address
02h on A7–A0 in word mode (or the address 04h on
A6–A-1 in byte mode) returns 01h if the sector is
protected, or 00h if it is unprotected. (Refer to Ta-
bles 3–6 for valid sector addresses).
The system must write the reset command to return to
the read mode (or erase-suspend-read mode if the
bank was previously in Erase Suspend).
Enter SecSi
TM
Sector/Exit SecSi Sector
Command Sequence
The SecSi Sector region provides a secured data area
containing a random, sixteen-byte electronic serial
number (ESN). The system can access the SecSi
Sector region by issuing the three-cycle Enter SecSi
Sector command sequence. The device continues to
access the SecSi Sector region until the system is-
sues the four-cycle Exit SecSi Sector command se-
quence. The Exit SecSi Sector command sequence
returns the device to normal operation. The SecSi
Sector is not accessible when the device is executing
an Embedded Program or Embedded Erase algo-
rithm. Table 14 shows the address and data require-
ments for both command sequences. See also
“SecSi
TM
(Secured Silicon) Sector Flash
Memory Region” for further information.
Byte/Word Program Command Sequence
The system may program the device by word or byte,
depending on the state of the BYTE# pin. Program-
ming is a four-bus-cycle operation. The program com-
mand sequence is initiated by writing two unlock write
cycles, followed by the program set-up command. The
program address and data are written next, which in
turn initiate the Embedded Program algorithm. The
system is
not
required to provide further controls or
timings. The device automatically provides internally
generated program pulses and verifies the pro-
相關(guān)PDF資料
PDF描述
DS324 32 Megabit (4 M x 8-Bit/2 M x 16-Bit) CMOS 1.8 Volt-only, Simultaneous Operation Flash Memory
DS323PIN Analog IC
DS3245
DS3245J Quad Clock Driver
DS3245N Quad Clock Driver
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
DS-323 制造商:MA-COM 制造商全稱:M/A-COM Technology Solutions, Inc. 功能描述:Flatpack Three-Way Power Divider 25 - 1000 MHz
DS3231 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Extremely Accurate I2C-Integrated
DS3231_10 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Extremely Accurate I2C-Integrated RTC/TCXO/Crystal
DS3231_1007 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Extremely Accurate I2C-Integrated RTC/TCXO/Crystal
DS3231_13 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Extremely Accurate I2C-Integrated RTC/TCXO/Crystal